- 9 -
"Service note".
1.
Unscrew the rear housing cap Item 1
2.
Release screw 2
3.
Remove the worn carbon brush 2 and insert a new one
4.
Tighten screw 2 and replace housing cap 1
8 Disposal:
Do not dispose of the device in the household waste! The device contains valuable
substances which could be recycled. If you have questions concerning this topic,
please contact your municipal disposal company or other appropriate municipal
institutions.
9 Malfunctions
Please note that for safety reasons you must disconnect the mains plug before you
replace the safety fuse!
9.1
Replacing the safety fuse
If the device fails, the safety fuse installed in the device
could be blown and must be replaced. The fuse is located
next to the socket for connecting the mains power input.
Simply twist out the fuse bracket with a slotted screwdriver
as shown in Fig. 6 and replace the fuse. Twist the bracket
back in.
Please use the following spare fuse: T2A/250 V
Fig. 6