background image

 

40 

 

“focus differently” 

www.xentino.com 

Xentino HSP500  User Manual 

Item

 

Default

 

Description

 

Enable Credit Card Service

 

Disable

 

Enables  or  disables  the  credit  card  service.  Before  you  enable  credit  card 
service,  make  sure  that  your  credit  service  is  configured  to  work  and  the 
currency  is  American  dollars.  You  must  be  converting  all  prices  on  your 
billing page into American dollars (U.S. dollars). For details, see section 3-2-
2-3  Credit  Card.  The  credit  card  function  only  supports  the  American 
dollars. 

No Billing Mode 

Disable 

If you would like to provide 

FREE

 Wi-Fi for users, please activate“No Billing 

Mode”the price and the tax won’t be showed on the ticket. 

Currency 

USD 

Enter the appropriate currency unit or currency symbol. 

Number of decimals places 

Enter the number. The field maximum value is 3. 

Tax Percentage 

Disable 

This check box is used to indicate the taxable status of the account. 

5% 

Enter the tax rate (i.e. a 5% sales tax is entered as 5). 

Time Base Profile

 

Time to Finish

 

Enable

 

The  subscriber  can  access Internet  only  one  time  with one  account.  Once 
subscriber login, the pre-defined usage time will start until run out even the 
subscriber stop to access the Internet before run out. 

Accumulation

 

Disable

 

The  subscriber  can  access  Internet  many  times  with  one  account.  The 
system  can  keep  and  accumulate  every  single  usage  time  until  the  pre-
defined usage time run out. 

You are able to set up to 10 records of time base profile in UI. 

Active 

Click on check box, active or inactive the billing profile. 

Name 

It is the name of billing profile. The maximum allowed characters length is 
12. 

Account Usage time 

The duration of the billing period. When this period expires, user account 
will be discontinued. 

Charge 

Enter  the  unit  rate  amount  (i.e.  35.00)  that  most  of  your  accounts  are 
charged for one day of service. 

Volume Base Profile

 

You are able to set up to 5 records of volume base profile in UI. 

Active 

Click on check box, to active or inactive the billing profile. 

Name 

It is the name of billing profile. The maximum allowed characters length is 
12. 

Account Usage time 

Setting  the  volume  of  the  account.  When  this  volume  is  run  out,  user 
account will be discontinued. 

Charge 

Enter the unit rate amount. 

 
 

 

Summary of Contents for HSP500

Page 1: ...HSP500 Wireless HotSpot Gateway with Printer USER MANUAL ...

Page 2: ...se of this product We reserve the right to change the product specification without notice Information in this document may change without notice Trademarks Microsoft Win98 Windows 2000 WinXP Win Vista and Win7 are registered trademarks of Microsoft Corporation Xentino are registered trademarks of Xentino Technologies Corporation General All other brand and product names mentioned herein may be re...

Page 3: ...nas 15 2 2 Installation Requirements 15 2 3 Getting Start 17 3 Configuringthe HSP500 19 3 1 Setting Wizard 19 3 2 Advanced Setup 34 3 2 1 AUTHENTICATION 35 3 2 1 1 Authentication 35 3 2 2 2 RADIUS 37 3 2 2 BILLING 39 3 2 2 1 Billing 39 3 2 2 2 Accounting 42 3 2 2 3 Credit Card 50 3 2 3 MANAGEMENT 53 3 2 3 1 Syslog 53 3 2 3 2 Session Trace 59 3 2 3 3 Bandwidth 61 3 2 3 4 SNMP 62 3 2 4 SECURITY 63 3...

Page 4: ...0 3 4 1 Configuration 101 3 4 2 Firmware Upgrade 102 3 4 3 Boot Code 105 3 4 4 Controller Board Firmware 105 3 4 5 System Account 106 3 4 6 SSL Certificate 110 3 4 7 Ping Command 111 3 4 8 Mode Setting 111 3 4 9 Restart 112 3 4 10 Logout 112 4 QR Code Service 113 4 1 QR code setting 113 4 2 Additional information for QR code use 114 4 3 Use QR code to access the Internet 115 5 Personal ID Recognit...

Page 5: ...her sites that commonly host business travelers and offers instant high speed Internet connections With its IP Plug and Play technology it accepts any client configuration login when client open browser the HSP500 immediately recognizes new end user and redirects their browser to customized Web pages There s no need for end user to change any of their default network Static IP e mail SMTP Server b...

Page 6: ...CD One Wi Fi Label If any of the above items are damaged or missing please contact your dealer immediately 1 2 Features Wireless data rates up to 300 Mbps Supports up to 30 simultaneous Users IP Plug and Play iPnP Comprehensive security 64 128 bit WEP encryption WPA encryption WPA2 Encryption IP URL filtering Intelligent Management Built in AAA Authentication Accounting Authorization and Billing m...

Page 7: ... injury if you touch these parts Never install the system in the wet locations Use only the original fitting AC power adapter otherwise there is a danger of severe electrical shock Avoid exposing the HSP500 to direct sunlight or another heat source Choose a well ventilated area to position your HSP500 1 4 Outlook Figure 1 4 1 HSP500 ...

Page 8: ...4 Button A 5 Button B 6 Button C 7 Push Button for printer cover opening 8 Reset Button 9 DC power supply connector 10 RJ45 port 11 Micro USB connector 12 WLAN LED Green 13 UPLINK LED Yellow 14 SMA connector 15 SMA connector WLAN LED Off The wireless is not ready Green light The HSP500 has established a valid wireless connection Green Blinking The wireless connection is active ...

Page 9: ...w light A port has established a valid 10 100 Mbps network connection Yellow Blinking 10 100 Mbps traffic is traversing the port Reset Button The HSP500 has a reset button at the rear panel of the device Use this function to reset the system back to factory defaults Power Jack Used to connect the external power supply with the HSP500 ...

Page 10: ...st page to make sure the printer is functioning properly To do this act as follows 1 Turn the printer off 2 Hold down the button A for approximately five seconds and then turn the printer on 3 The printer will print a test page 1 4 2 How to load paper rolls Please follow the steps to correctly load paper rolls 1 2 3 4 Figure 1 4 4 Paper rolls loading ...

Page 11: ...s One WAN Port 10BaseT 100BaseTXAuto cross over One Micro USB connector Encryption WEP Wired Equivalent Privacy 64 128 bit RC4 WPA Wi Fi Protected Access WPA2 Wi Fi Protected Access External Antenna Type Dual detachable diversity antenna with reverse SMA LED Indicators One POWER LED One WAN 10 100M Link Activity LED One Wireless Link Activity LED One System LED Power Requirement External Power Ada...

Page 12: ...ter cover is opened Paper roll housing put paper roll here Paper Roll and Printing Paper width 58 0 1 mm Paper length 50M max Paper thickness 65 um Paper roll outside diameter 63 2 2 mm Paper roll inside diameter 12 0 5 0 mm Paper Detection Photo interrupter Printing width 48 mm Printing Method Direct thermal Printing Speed 25 4 mm sec Dot resolution dots mm 8 203 dpi Thermal head service life 1 p...

Page 13: ...16 PPTP WAN Client NAT RFC 1631 IP Routing NTP Network Time Protocol Support Local Account 256 Max Session Number up to 16384 Marketing Cooperation Advertisement URL link Walled garden Customizable log on and log off pages Portal Page User Accounting and Authentication Built in Authentication Web based Authentication RADIUS AAA Support RFC 2865 2866 Secondary RADIUS User Authentication and Account...

Page 14: ...s through PPTP VPN Client WEP WPA WPA2 WPA WPA2 Mix mode Management Web based Management Tool Firmware Upgrade via HTTP TFTP Wizard setup for step by step Configuration Backup Restore Factory Default Setting Remote Authorized Management Real time Session List Syslog System Subscriber LAN device E mail logs SNMP v1 v2 MIB II Private MIB System Information Table Status Report Daily Monthly System Ne...

Page 15: ...OS and UNIX TCP IP protocol installed Standard phone line for xDSL modem Or Coaxial cable for Cable modem Web Browser Software Microsoft I E 5 0 or later version or Netscape Navigator 5 0 or later version One computer with an installed 10Mbps 100Mbps or 10 100Mbps Ethernet card UTP network Cable with a RJ 45 connection Package contents Note Prepare twisted pair cables with RJ 45 plugs Use Cat 5 ca...

Page 16: ...et mask from your ISP Your user name from your ISP Your password from your ISP Your PC Requirements The Static IP settings for the PC Your PC s fixed IP address Your PC s subnet mask Your PC s default gateway IP address Your PC s primary DNS IP address Note 1 The gateway s default IP address setting is 10 59 1 1 2 The gateway s default subnet mask setting is 255 255 255 0 The Dynamic IP settings f...

Page 17: ...focus differently www xentino com 2 3 Getting Start HSP500 Connection 1 Connect the DC power adapter to the HSP500 and plug it into a power socket 2 Connect HSP500 and xDSL modem with an Ethernet Cable Figure 2 3 1 HSP500 Connection ...

Page 18: ...witch to Classic View and double click on Network Connections 2 Right click on the Local Area Connection and click Properties 3 Double click Internet Protocol TCP IP 4 Choose Obtain an IP address automatically 5 Click OK to close the Internet Protocol TCP IP Properties and click OK again to close the Local Area Connection Figure 2 3 2 TCP IP Setting ...

Page 19: ...art your browser and then enter the factory default IP address 10 59 1 1 in your browser s location box Press Enter Figure 3 1 1 Web Browser Location Field Factory Default Step 3 The HSP500 configuration tools menu will appear In the Username and Password field type the factory default user name admin and password admin and click Login If you are first time setting the system the wizard setup scre...

Page 20: ...20 Xentino HSP500 User Manual focus differently www xentino com Figure 3 1 3 Wizard Setup Screen Figure 3 1 4 System Quick View ...

Page 21: ...tion type to connect to your ISP Figure 3 1 5 Internet Connection Setting Screen DHCP Client The device can work as a DHCP client This allows the device to obtain the IP address and other TCP IP settings from your ISP If your xDSL Cable comes with this feature please enable Use DHCP Client Figure 3 1 6 Internet Connection Setting Screen ...

Page 22: ...e IP address provided by your ISP Subnet Mask 0 0 0 0 Enter the subnet mask for the IP address Gateway IP Address 0 0 0 0 Enter the Gateway IP Address provided by your ISP Primary DNS Server Empty Enter the primary DNS server IP address for the xDSL Cable connection provided by your ISP Secondary DNS Server Empty Enter the secondary DNS server IP address for the xDSL Cable connection provided by y...

Page 23: ...MTU Setting 1492 MTU Maximum Transfer Unit specifies maximum transmission unit size TCP MSS Setting 1452 MSS Maximum Segment Size specifies maximum segment size Service Name Empty Enter the service name provided by your ISP The service name can consist of up to 64 alphanumeric characters and is case sensitive Connect on Demand and Max Idle Time Connect on Demand Enable You can configure your HSP50...

Page 24: ...o Point Tunneling Protocol If PPTP Setting is selected then this screen will appear Please enter the IP address Username and Password provided by your ISP Figure 3 1 9 Internet Connection Setting Screen PPPoE Setting Item Default Description Username Empty Enter the user name provided by your ISP The user name can consist of up to 80 alphanumeric characters and is case sensitive Password Empty Ent...

Page 25: ... time Max Idle Time If you have been disconnected due to inactivity Connect on Demand enables your HSP500 to automatically re establish your connection as soon as you attempt to access the Internet again If you wish to activate Connect on Demand click the radio button If you want your Internet connection to remain click the radio button of keep alive The Max Idle Time maximum value is 65535 minute...

Page 26: ...ose Country Channel ID and 802 11 Mode for wireless connection Figure 3 1 10 Wireless Setting Screen Item Default Description Country ETSI Enter the Country for wireless connection Channel 6 Enter the channel ID for wireless connection 802 11 Mode 802 11n 802 11g 802 11b Enter the 802 11 Mode for wireless connection ...

Page 27: ...m Step 6 Authentication Setting This page allows you to choose whether the users need to be authenticated before the Internet access If users need the account and password to get access of Wi Fi please choose Yes Figure 3 1 11 Authentication Service Setting Screen ...

Page 28: ...age allows you to set your service and price plan If you would like to provide FREE Wi Fi for users please activate No Billing Mode the price and the tax won t be showed on the ticket The billing type could be set by time based or by volume based Time Base Profile Figure 3 1 11 Billing Profile Setting ...

Page 29: ...an decide the currency printed out on the ticket Service and Price Plan Time to Finish Choose your service and price plan Time Base Profile 01 02 03 You could set the profile name usage time and charge here You could set 3 different profiles in this step Volume Based Profile Figure 3 1 13 Billing Profile Setting Volume base Item Default Description Volume Base Profile 01 02 03 You could set the pr...

Page 30: ...ult Description Setting Button A Button B Button C You could choose the billing profile via the dropdown list for each button on the printer Printout Numbers of copies to print 1 The numbers of the same printed tickets You can reserve the copies Customize printout ticket You can customize the printout text for the ticket If you want to know more please refer to Error Reference source not found Err...

Page 31: ...al focus differently www xentino com Step 9 Firmware Upgrade Notice Setting If you would like to receive the information about firmware upgrade please activate it and leave your email Figure 3 1 15 Firmware Upgrade Notice Setting ...

Page 32: ...Setting Screen Item Default Description Username admin Enter the user name The user name can consist of up to 80 alphanumeric characters and is case sensitive Password admin Enter the user password The password can consist of up to 80 alphanumeric characters and is case sensitive Time Zone GMT Enter the Time Zone for the system Manual Setting YYYY MM DD HH MM SS Click Manual Setting to set the sys...

Page 33: ...tem will restart Note 1 This Web agent is best viewed with IE 5 0 or Netscape 6 0 and above browsers 2 Username and Password can consist of up to 20 alphanumeric characters and are case sensitive 3 If for some reason your password is lost or you cannot gain access to the HSP500 Configuration Program please press the reset button to load the device to manufacturer defaults 4 If the administrator do...

Page 34: ...AUTHENTICATION AUTHENTICATION RADIUS BILLING BILLING ACCOUNTING CREDIT CARD MANAGEMENT SYSLOG SESSION TRACE BANDWIDTH SNMP SECURITY PASS THROUGH FILTERING SECURE REMOTE SYSTEM SYSTEM WAN LAN SERVER CUSTOMIZATION PORTAL PAGE ADVERTISEMENT WALLED GARDEN DDNS WIRELESS Figure 3 2 1 Advanced Setting Item Note After change the settings of device please click Apply button to save the new settings ...

Page 35: ... service provider can generate the subscriber account inside the device and the system will authenticate the subscriber login according to the generated account Personal ID Recognition mode Some countries or areas will ask Wi Fi users to offer personal ID recognition according to the law for the Internet crime investigation If you would like to activate PIR function please refer to Chapter 5 Perso...

Page 36: ...ation Backup 1 Min s The system provides automatically backup account information and unused account to flash ROM This function allow administrator to adjust the backup time The default value is 1 minute The Current User Information Backup valid range is 1 to 1440 SSL Login Page Disable Enables or disables SSL security of login page User Idle Time Out 5 Minutes The user idle time out valid range i...

Page 37: ...provider to build up an Internet service with RADIUS server If RADIUS Authentication is enabled all subscribers authentication will send to RADIUS Server by RADIUS protocol RFC 2865 2866 Time to Finish Accumulation Enable Service provider provides two different accounting calculate for the Internet service Primary RADIUS Server Server IP Empty Enter the IP address of RADIUS server Authentication P...

Page 38: ...port number must match with the secondary RADIUS server setting The allowed numbers are from 0 to 65535 Share Secret Key Empty The share secret key the key number also has to match with the secondary RADIUS Server setting Up to 64 characters are allowed Retry times when Primary fail 1 Specify the retry times when primary fail Retry Frequency Seconds 3 The field default value is 3 seconds Accountin...

Page 39: ...xentino com Xentino HSP500 User Manual 3 2 2 BILLING 3 2 2 1 Billing The function is used to setup a billing profile A billing profile is a description of how you want to charge your customer Figure 3 2 5 Billing Setting Screen ...

Page 40: ...iber can access Internet only one time with one account Once subscriber login the pre defined usage time will start until run out even the subscriber stop to access the Internet before run out Accumulation Disable The subscriber can access Internet many times with one account The system can keep and accumulate every single usage time until the pre defined usage time run out You are able to set up ...

Page 41: ...41 focus differently www xentino com Xentino HSP500 User Manual Figure 3 2 6 Accumulation and Time to Finish Figure 3 2 7 Pre paid Procedure Diagram ...

Page 42: ...nt will be deleted after hours automatically 24 hours Enter the number of hours minutes days The field maximum value is 30 hours minutes days Accumulation account will be deleted after last logged in 3 months Enter the number and select time unit from list box The field maximum value is 30 month days hours Printout Number of copies to print 1 The system allows you to print all your bills Select on...

Page 43: ... Name shown on Login Page Free Trial for 30 minute s You could customize the text that shown on user login page The maximum allowed characters length is 30 Free Trial base By Usage time You could set the free trial to be based by time or by volume and you could also define the usage of free trial Reset Time 00 00 The gratuitous usage amount of free Trial is on a periodic time basis The Reset Time ...

Page 44: ...r Enable Item Default Description Button A C Define each button s billing profile Select one billing profile by clicking in the list box Use for Discount Price Plan based on Button Presses Button A Disable Select one button A C by clicking in the list box to assign the base charge and select enable to active the discount price plan ...

Page 45: ...45 focus differently www xentino com Xentino HSP500 User Manual Figure 0 2 Account Generator Printer Time to Finish Figure 0 3 Account Generator Printer Accumulation ...

Page 46: ...ifferently www xentino com Xentino HSP500 User Manual Example If press 7 times Discount Price Plan based on Button Presses is disabled Figure 3 2 13 Example 1 Amount 7 x 2 00 14 00 Figure 3 2 14 Account Printout ...

Page 47: ...com Xentino HSP500 User Manual Figure 3 2 16 Account Printout Discount Price Plan based on Button Presses is enabled The Charge by level is disabled Figure 3 2 15 Example 2 Amount 7 x 1 7 00 Below is an example of the account printout ...

Page 48: ...ntino HSP500 User Manual Figure 3 2 18 Account Printout Discount Price Plan based on Button Presses is enabled Charge by level is enabled Figure 3 2 17 Example 3 Amount 2 x 2 00 4 x 1 50 1x 1 11 00 Below is an example of the account printout ...

Page 49: ... levels Enable Enables or disables the charge by levels function Level 1 10 This field displays the level number of charge rate Conditions When The discount condition Button Presses Enter the times of pressing button Unit Price Enter the amount of charge level Click Apply button to save the new settings and the success dialog box appears Click on Back to return to Accounting setting screen ...

Page 50: ...nual 3 2 2 3 Credit Card HSP500 provides three credit card services Authorize net iValidate net Secure Pay and Paypal that allow service provider to authorize process and manage credit transactions directly from Internet Figure 3 2 20 Credit Card Setting Screen ...

Page 51: ...ation included subscriber username and password would be sent to subscriber Email Additional Information Disable Indicates whether Email additional information should be sent to the subscriber customer Merchant Name Empty Enter the merchant s company name The maximum allowed characters length is 40 Username and Password Enable Disable Disable The Email Additional Information included subscriber us...

Page 52: ...in webscr Enter the address of Payment Gateway The maximum character of the payment gateway is 100 World Pay Payment Gateway select worldpay com w cc purchase Enter the payment gateway address Installation ID Empty The unique reference number assigned by WorldPay for a particular Select installation This is the number you send to WorldPay in your payment form You will probably have at least two of...

Page 53: ...oting Syslog Setting Figure 3 2 21 Syslog Setting Screen Item Default Description Send to Syslog Server Disable Enables or disables the syslog server function Syslog on LAN Server IP Address Empty Enter syslog server s IP address The HSP500 will send all of its logs to the specified syslog server Server MAC Address Empty Enter the syslog server s MAC address The HSP500 will send all of its logs to...

Page 54: ...rd are supplied by your network administrator SMTP server provider or ISP Username Empty Enter the username for the SMTP server The maximum allowed characters length is 64 Password Empty Enter the password for the SMTP server Email From Name Empty Enter the name you would like to appear in the message from field of your outgoing message The maximum allowed characters length is 20 Email Address Emp...

Page 55: ...55 focus differently www xentino com Xentino HSP500 User Manual Log Categories Figure 3 2 22 Log Settings Screen ...

Page 56: ... 0e 00 00 01 LANMAC 09 00 0e 00 00 02 WLANMAC 09 00 0e 00 00 03 IP_ADDRESS 210 66 37 21 SYS_NAME Cafehotspot LOCATION East CITY Taipei COUNTRY Taiwan FIRMWARE v1 01 02 MESSAGE System_Up Message System_Reboot System Account Activity Information When system manager login or logout A log will be sent if system manager Administrator login to or logout from the device Format PRODUCT HSP500 VER 2 00 00 ...

Page 57: ..._MAC 02 34 3e 01 00 INTERFACE Ethernet USER_TYPE Dynamic User Type Dynamic Super User Agreement Radius No Auth When User Replenish login format PRODUCT HSP500 VER 2 00 00 LOGNAME URP DATE 07Mar26 TIME 15 23 32 WANMAC 09 00 0e 00 00 01 LANMAC 09 00 0e 00 00 02 WLANMAC 09 00 0e 00 00 03 IP_ADDRESS 210 66 37 21 USER_NAME asdfg12 REP_USER_NAME kifm2fs3 USER_IP 10 59 1 1 USER_MAC 02 34 3e 01 00 INTERFA...

Page 58: ...o Auth the username Account and Billing Account Information When an account is created A log will be sent when an account is created Format PRODUCT HSP500 VER 2 00 00 LOGNAME ACI DATE 07Mar26 TIME 15 23 32 WANMAC 09 00 0e 00 00 01 LANMAC 09 00 0e 00 00 02 WLANMAC 09 00 0e 00 00 03 IP_ADDRESS 210 66 37 21 USER_NAME asdfg12 ACCOUNT_TYPE TimetoFinish ACCOUNT_SERIAL 000002 ACCOUNT_PRICE USD20 00 ACCOU...

Page 59: ...ce provider to trace every user s access behavior When session trace is enable the system will collect information such like destination IP destination port source IP source MAC source port by every user and send the collected information in text format file to specified TFTP server or Email Server Figure 3 2 23 Session Trace Setting Screen ...

Page 60: ... SMTP Port Empty The SMTP port allowed range is 25 or 2500 to 2599 E mail SMTP Server needs to check my account Disable If your SMTP server requires authentication before accepting e mail click on check box These values username and password are supplied by your network administrator SMTP server provider or ISP Username Empty Enter the username for the SMTP server The maximum allowed characters le...

Page 61: ...ts users from consuming a disproportionately large amount of bandwidth so every user gets a fair share of the available bandwidth Figure 3 2 24 Bandwidth Setting Screen Item Default Description Bandwidth Disable Enables or disables Bandwidth Management Maximum Upstream 64Kbps Specify the amount of upstream bandwidth Maximum Downstream 128Kbps Specify the amount of downstream bandwidth ...

Page 62: ...port numbers are 161 default 16100 16199 and Trap port numbers are 162 default 16200 16299 This Port setting is useful for remote control via NAT network Trap Port 162 Configuration Community Name public private Every unit with SNMP enable must be configured to recognize one or more community names up to 20 characters The default setting for the community of entry 1 is public and for the entry 2 i...

Page 63: ... and the administrator can control which devices can be pass through with authentication Figure 3 2 26 Pass through Setting Screen Item Default Description Pass Through Disable Enables or disables the pass through function Destination URL IP Address Pass Through URL or Website Empty Enter the URL Page please use this format such like http www yahoo com The maximum character of the URL Page is 50 N...

Page 64: ...of you wants pass through Mask Empty Enter the subnet mask of you wants pass through Pass Through List Display the pass through Information of HSP500 No The index number of pass through address Active Disable Click on check box active or inactive the pass through address Address List Display the pass through address s Type Display the type of pass through address Delete Disable Select the check bo...

Page 65: ...cked The Web Site is blocked by System Enter the http message The maximum character of the HTTP message is 200 Restrict Destination URL or Website Empty Enter the URL Page of you wants to filter please use this format such like http www yahoo com The maximum character of the URL Page is 50 Start IP Address Empty Enter the start IP address of you wants to filter IP Address Empty Enter the destinati...

Page 66: ...ess List Display the filtering address s Delete Disable Select the check boxes and click Delete to delete the filtering address s Click Add to List button to add a new entry Click Apply button to save the new settings Click Delete All Apply button to delete all entries ...

Page 67: ...he check box to automatically establish the PPTP connection PPTP Server IP address Empty Enter the PPTP server IP address provided by your ISP Username Empty Enter the user name provided by your ISP The user name can consist of up to 80 alphanumeric characters and is case sensitive Password Empty Enter the user password provided by your ISP The password can consist of up to 80 alphanumeric charact...

Page 68: ...68 focus differently www xentino com Xentino HSP500 User Manual 3 2 5 SYSTEM 3 2 5 1 System Define the HSP500 System configuration Figure 3 2 29 System Setting Screen ...

Page 69: ...Time 0 hours Enter the number of hours for update time Daylight Saving Time Disable Enables or disables Daylight Saving Time DST Month Day Set the Daylight Saving Time DST on the HSP500 Adjust the begin time and end time NAT Network Address Translation NAT Enable Enables or disables NAT Address Translation function User Session Limited Enable 300 Enables or disables user session limit function Thi...

Page 70: ...a certificate one is purchase a certificate from a certificate authority Ex Verisign or Thawte and another is creating a self certificate For example Uses OpenSSL tool Multi Press Enable If the Multi Press is enabled the unit on the ticket will equal to the times of press at one time So the venue could control the unit on each ticket by Multi press function If the Multi Press is disabled The unit ...

Page 71: ...71 focus differently www xentino com Xentino HSP500 User Manual 3 2 5 2 WAN LAN Figure 3 2 30 WAN LAN Setting Screen ...

Page 72: ...ser Name Empty Enter your PPPoE account name The user name can consist of up to 80 alphanumeric characters and is case sensitive Password Empty Enter your PPPoE password The password can consist of up to 80 alphanumeric characters and is case sensitive PPP MTU Setting 1492 MTU Maximum Transfer Unit specifies maximum transmission unit size TCP MSS Setting 1452 MSS Maximum Segment Size specifies max...

Page 73: ...ystem under NAT please tab the http HTTP Port IP Address Port Number HTTPS Port 443 Enter the HTTPS port number The HTTPS port allowed range is 443 or 4430 to 4440 For access the HSP500 system please tab the https HTTPS Port IP Address Port Number Administrator Idle Timeout 5 Minutes The idle time out valid range is 1 1440 If the idle time out is set as 5 minutes it means if the administrator does...

Page 74: ...minutes Primary DNS Server 168 95 1 1 Enter the IP address of the network s primary DNS server Secondary DNS Server Empty Enter the IP address of a second DNS server on the network Email Server Redirect To prevent some subscriber s original Email server may protect by firewall or NAT network HSP500 provides an extra Email server parameter to forward the subscriber s Email The HSP500 not only forwa...

Page 75: ...idual computers based on their MAC Address Figure 3 2 32 Server Setting Screen Item Default Description IP Address Empty Enter the IP address that subscriber want to assign to the computer on LAN with the MAC address the subscriber will also specify MAC Address Empty Enter the MAC address of a computer on your LAN Click Apply button to save the new settings ...

Page 76: ...w xentino com Xentino HSP500 User Manual 3 2 5 4 Customization Login Page The HSP500 provides three different login page formats including standard redirect advanced and frame format Figure 3 2 33 Customization Setting Screen ...

Page 77: ...mum allowed characters length is 80 Footnote Disable Allow the administrator to input the footnote such like Pleas Contact to our Customer Service Center EXT 141 The maximum character of the footnote is 240 Copyright Enable The copyright is allowed the administrator to input a paragraph in the subscriber login page for copyright information The maximum character of the copyright is 80 Background C...

Page 78: ...nt or announcement The maximum character of the article is 1024 Article Text Color 000000 The article text color can be specified color For the specified text color format please views the color grid The allowed format is Hexadecimal Article Background Color None The article background can be specified color For the background color format please views the color grid The allowed format is Hexadeci...

Page 79: ...nd password input Top Frame is allowed to be specified a URL to link Top Frame URL Link Empty The input format can be http www yahoo com The maximum character of the URL Link is 200 Bottom Frame This frame will show the standard login page Figure 0 6 Example Login Page Screen Logo This function allows service provider to upload the customer s logo image file which can be shown on the standard logi...

Page 80: ...utton to delete the logo file InformationWindow This function allow service provider can decide whether they want an Information Window pop up on subscriber PC when authenticate successful or not and specified text of information window Subscriber can type http 1 1 1 1 info to open the information window again or enter http 1 1 1 1 logout to logout immediately if accumulation billing selected Figu...

Page 81: ...an be topped up by subscriber Enable Figure 0 8 Information Window Billing Type Accumulation Can be topped up by subscriber Disable Figure 0 9 Information Window Billing Type Accumulation Can be topped up by subscriber Enable Window Name Main message Message Description Time count label Warning Alarm message Notice Message ...

Page 82: ...anual Figure 0 10 Information Window Account Printout This function allow service provider to specified text of account printout Figure 0 11 Account Printout Customization Setting Screen Note If you don t print out QR code on the ticket please disable QR Code ...

Page 83: ...83 focus differently www xentino com Xentino HSP500 User Manual Credit Card Figure 0 12 Credit Customization Setting Screen ...

Page 84: ...w service provider to customize the additional credit card message for the standard login page Fail Page This function allow service provider to customize the message for the fail page Click Apply button the success dialog box appears Click on Back to return to Credit Card Customization setting screen User Agreement Page This function allow user to design user agreement page of Internet Subscriber...

Page 85: ... specified portal page after successful login Figure 3 2 46 Portal Page Setting Screen Item Default Description URL Link Empty Enter the URL Link page The input format can be http www yahoo com The maximum character of the URL Link is 200 Click Apply button the success dialog box appears Click on Back to return to Portal Page setting screen ...

Page 86: ...y interval minutes The value range is 1 to 60 minutes Sequence Randomly Randomly Displaythe advertisement page in the random order From 1 to 10 Display the advertisement page in the order as setting URL Link 1 5 Empty This function allows the administrator to input ten different websites in the table for advertisement And these 5 websites will display to the subscribers at random when the subscrib...

Page 87: ... trying and can use for advertisement Figure 3 2 48 Walled Garden Setting Screen Item Description Name The name is allowed user to set the prompt string in user customize login page The maximum allowed characters length is 80 URL 1 5 The input format can be http www yahoo com The maximum character of the Link is 200 Click Apply button the success dialog box appears Click on Back to return to Walle...

Page 88: ...ses etc can be stored and retrieved This solves the problems if your DNS server uses an IP associated with dynamic IP addresses When the ISP assigns the HSP500 a new IP the HSP500 must inform the DDNS server the change of this IP so that the server can update its IP to DNS entry Once the IP to DNS table in the DDNS server is updated the DNS name for your web server i e xyz dyndns org is still usab...

Page 89: ...running Update Fail DDNS Client service installed service not running Service Provider Dyndns org www dyndns org Select a DDNS service provider by clicking in the list box Note Before configuring the DDNS settings you have to register a dynamic domain at one of the dynamic domain service providers list box Registered Host Name Empty Enter the host name of DDNS server The maximum character of the r...

Page 90: ...al Settings Country ETSI Enter the Country for wireless connection Channel 6 Select the channel ID for wireless connection 802 11 Mode 802 11n 802 11g 802 11b Enter the 802 11 Mode for wireless connection Channel Width Auto 20 40 MHZ Select the Channel Width for wireless connection Multiple ESSID Setting Click Edit button for each of 8 ESSID setting ...

Page 91: ...sensitive and must not exceed 32 characters Broadcast Enable This allows you to show or hide the ESSID name when users search the Wi Fi signal Security Settings Security Open Select Open to allow wireless station to communicate with the device without any data encryption Select WPA WPA2 MixMode for data encryption Group Key Re Keying 86400 Seconds Enter a number in the field to set the force re ke...

Page 92: ...client devices are associating with the HSP500 or in areas where the clients are far apart and can detect only the HSP500 and not each other Fragmentation Threshold 2432 This setting determines the size at which packets are fragmented Enter a setting ranging from 256 to 2432 bytes Use a low setting in areas where communication is poor or where there is a great deal of radio interference Preamble T...

Page 93: ...ged in a USB to Ethernet adapter can expand the HSP500 Wi Fi signal range The administrator can connect HSP500 USB port to another AP router Ethernet port with a USB 2 0 to RJ45 Ethernet network adapter After the activation the administrator can change the ESSID Figure 0 14 USB Setting Screen ...

Page 94: ...w xentino com Xentino HSP500 User Manual 3 3 System Status Display HSP500 system basic status including 1 System 2 Account List 3 Account Log 4 Current User 5 DHCP Clients 6 Session List Figure 3 3 1 System Status Item Screen ...

Page 95: ...3 3 1 System The System Information Menu displays current system basic information including the service connection message host name LAN WAN DHCP Configuration DNS E mail Redirection SSL Certificate network traffic Information and the system firmware version number ...

Page 96: ...ord usage time time created login time expiration time and status Figure 3 3 3 Account List Click refresh button to update the account list page Click the column button S N Status Username etc to sort the column in ascending descending order Select the check boxes and click Delete to delete the accounts Click Delete ALL button to delete all accounts in account list Note This page will refresh auto...

Page 97: ... information Figure 3 3 4 Account Log Click Export to export the account logs to a text file format export log Click Clear Log button to remove all account log entries Click refresh button to update the account log page Click the column button S N Username Time Created etc to sort the column in ascending descending order ...

Page 98: ...ider to disconnect any subscribers Figure 3 3 5 Current User List Click refresh button to update the current user list page Click the column button Interface Type Username IP Address etc to sort the column in ascending descending order Select the check boxes and click Delete to delete accounts Click Delete ALL to delete all accounts in current user list ...

Page 99: ...al 3 3 5 DHCP Clients The DHCP client table shows the current DHCP users on the LAN Figure 3 3 6 Current User Screen 3 3 6 Session List The remote site administrator could monitor the real time usage status of HSP500 via this page Figure 3 3 7 Session List Screen ...

Page 100: ... allows service provider or administrator to process Firmware upgrade change password and backup or restore configuration 1 Configuration 2 Firmware 3 Boot Code 4 Controller Board Firmware 5 System Account 6 SSL Certificate 7 Ping Command 8 Restart 9 Logout Figure 3 4 1 System Tools Item ...

Page 101: ...Name Empty Enter the file name in the File Name field Restore Click it to restore your system configuration Local PC File Path Empty Enter the file pathname of the system configuration file in the Local PC File Path field Remote TFTP Server IP Address Empty Enter the IP address of TFTP Server File Name Empty Enter the file name in the File Name field Reset the system back to factory defaults Erase...

Page 102: ...e Setting Screen Item Default Description This allow administrator to upgrade the firmware via HTTP Local PC File Path Empty Enter the file name and location in the Local PC File Path field This allows administrator use TFTP server to upgrade firmware Remote TFTP Server IP Address Empty Enter the IP address of TFTP Server File Name Empty Enter the file name in the File Name field Note 1 Before dow...

Page 103: ... Setting Screen Item Default Description Disable Enable Disables or enables the scheduled firmware upgrade function TFTP Server IP Empty Enter the IP address of TFTP Server File Synchronization Empty Enter the file name and location in the File Synchronization field View Sample File Click the button to display synchronization file example Figure 3 4 5 Synchronization File Sample Code Frequency Wee...

Page 104: ... the information about firmware upgrade please activate it and leave your email You should enable Agree that Xentino will be able to contact me if there is new firmware version release before filling in the email address Figure 0 1 Synchronization File Sample Code Item Default Description Email Empty Enter the email address for firmware upgrade information Reconfirm your mail Empty Re enter the em...

Page 105: ... differently www xentino com Xentino HSP500 User Manual 3 4 3 Boot Code Figure 3 4 7 Boot Code Upgrade Setting Screen 3 4 4 Controller Board Firmware Figure 3 4 8 Controller Board Firmware Upgrade Setting Screen ...

Page 106: ...106 focus differently www xentino com Xentino HSP500 User Manual 3 4 5 System Account Use the System Account screen to change the system accounts Figure 3 4 9 System Account Setting Screen ...

Page 107: ...1440 minutes If the idle time out is set as 5 minutes it means if the accountdoesn t send packet in 5 minutes the account will logout automatically Administrator Account Step 1 Start your Web browser and enter the factory default IP address 10 59 1 1 in your browser s location box Press Enter Figure 3 4 10 Web Browser Location Field Factory Default Step 2 The HSP500 configuration main menu will ap...

Page 108: ... 12 Web Browser Location Field Factory Default Step 2 The HSP500 configuration main menu will appear Enter account as the Username and account as the password and click Login Figure 3 4 13 Web Based Accounting Manager Login Screen SupervisorAccount Step 1 Start your Web browser and enter the factory default IP address 10 59 1 1 in your browser s location box Press Enter Figure 3 4 14 Web Browser L...

Page 109: ...ain menu will appear Enter supervisor as the Username and supervisor as the password and click Login Figure 3 4 15 Supervisor Account Login Screen Step 3 After a valid user name and password have been provided the HSP500 configuration homepage will appear WIZARD SETUP and ADVANCED SETUP are disabled ...

Page 110: ...r super as the Username and super as the password and click Enter you can use Internet now Figure 3 4 16 Subscriber Login Page 3 4 6 SSL Certificate The function allows you to download the registered CA certificate into the HSP500 Figure 3 4 17 SSL Certificate Download Setting Screen Note The password field must the same as the CA s registered password ...

Page 111: ... Mode Setting The default setting of HSP500 is a Hotspot with printer but you could set it to be an account generator work with Internet Subscriber Server or Hotspot Gateway such as HSS700 and HSP607 Choose the mode setting you want for your HSP500 then click Apply the device will re boot and change the operating mode For detail operating instructions of HSP500 Printer Mode please refer to HSP500 ...

Page 112: ...g correctly you can choose this option to display the restart HSP500 screen Clicking the apply button restart the HSP500 with all of your settings remaining intact Figure 3 4 20 Restart Screen 3 4 10 Logout If you would like to leave the configuration page please click apply to exit Figure 3 4 21 Logout Screen ...

Page 113: ...de Service 4 1 QR code setting Please find Advance setting Customization Account Printout QR code If you don t print out the QR Code on the ticket please disable it and click Apply button Step 1 Step 2 Enable QR Code Step 3 Click Apply Figure 4 1 1 QR Coding Setting Screen ...

Page 114: ...nable 3 Add www apple com into PASS THROUGH list in HSP500 because iOS6 device and later is required 4 Click Add to List button 5 Choose Active on the Pass Through List For certain QR code Apps please add go redirectingat com 54 225 129 12 and 23 23 152 51 for APP ScanLife and follow the above steps Step 1 Step 2 Choose Enable Step 3 Add www appale com Step 4 Click Add to List Step 5 Choose Active...

Page 115: ...ps to access the Internet for clients 1 Print out the Ticket You can find the ESSID and WPA WPA2 printed on the ticket Figure 4 3 1 QR Coding Ticket 2 Connect to the ESSID ex Xentino_HSP500 input WPA WPA2 password ex 1234567890 Figure 4 3 2 Password Input Screen Verify to connect the correct ESSID Input the WPA WPA2 password ...

Page 116: ...HSP500 User Manual focus differently www xentino com 3 Open up QR code APP and Scan Figure 4 3 3 Scan 1 Screen 4 Some Apps may require user to click Go to URL Figure 4 3 3 Scan 2 Screen Scan QR code Click Go to URL ...

Page 117: ...117 Xentino HSP500 User Manual focus differently www xentino com 5 Client can use the Internet now Figure 4 3 4 Scan Finish Screen ...

Page 118: ...rime investigation HSP500 provides the function Personal Identification Recognition The default is disabled Subscribers need to activate it by the following steps 5 1 Personal ID Recognition Setting Step1 Active the function Go to Advanced Setup Authentication Authentication Enable the Personal ID Recognition Mode Please refer to Chapter Error Reference source not found Error Reference source not ...

Page 119: ...ofile in the Personal ID Recognition mode Please refer to Chapter Error Reference source not found Error Reference source not found to modify your first billing profile Figure 0 2 Billing Setting Screen Step 3 Start your browser and then enter the factory default IP address 10 59 1 1 in your browser s location box Press Enter Figure 0 3 Web Browser Location Field Factory Default ...

Page 120: ... account and click Login Figure 0 4 Configuration Tools Menu Step 5 ONLY account manager can operate PIR and printout the ticket There are 3 types for the account manager to choose including Driver License NO Passport No and Identify card No Fill in numbers and click or for usage time Click the Print button to printout the ticket Click View Account List to see all accounts which are printed out Fi...

Page 121: ...121 Xentino HSP500 User Manual focus differently www xentino com Figure 0 6 PIR Ticket Step 6 Click Logout and then click the Apply button to finish it Figure 0 7 Logout ...

Page 122: ...unshielded twisted pair UTP or shield twisted pair STP cable to connect the networking device to the RJ 45 Ethernet port Depending on the type of connection 10Mbps or 100Mbps use the following Ethernet cable as prescribed 10Mbps Use EIA TIA 568 100 Category 3 4 or 5 cables 100Mbps Use EIA TIA 568 100 Category 5 cable Figure RJ 45 Connector and Cable Pins Note To prevent loss of signal make sure th...

Page 123: ...es uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and ...

Page 124: ...ies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body NCC Statement 根據NCC低功率電波輻射性電機管理辦法規定 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或 使用者均不得擅自變更頻率 加大功率或變更原設計之特性及 功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經 發現有干擾現象時 應立即停用 並改善至無干擾時方得繼續 使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射...

Page 125: ...d with the product b Repair or attempted repair by anyone not authorized by us c Any damage of the product due to shipment d Removal or installation of the product e Causes external to the product such as electric power fluctuations or failure f Use of supplies or parts not meeting our specifications g Normal wears and tears h Any other cause that does not relate to a product defect 3 Removal inst...

Page 126: ...N INCONVENCE LOSS OF USE OF THE PRODUCT LOSS OF TIME LOSS OF PROFITS LOSS OF BUSINESS OPPORTUNITY LOSS OF GOODWILL INTERFERENCE WITH BUSINESS RELATIONSHIPS OR OTHER COMMERCIAL LOSS EVEN IF ADVISED OF THE POSSIBLITY OF SUCH DAMAGES 2 ANY OTHER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE 3 ANY CLAIM AGAINST THE CUSOMER BY ANY OTHER PARTY ...

Reviews: