background image

2

XENYX 1204/1204FX

This symbol, wherever it appears, alerts you to the

presence of uninsulated dangerous voltage inside

the  enclosure—voltage  that  may  be  sufficient  to

constitute a risk of shock.

This  symbol,  wherever  it  appears,  alerts  you  to

important operating and maintenance instructions

in  the  accompanying  literature.  Please  read  the

manual.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION:

To reduce the risk of electric shock, do not remove

the  top  cover  (or  the  rear  section).  No  user

serviceable parts inside; refer servicing to qualified

personnel.

WARNING:

To reduce the risk of fire or electric shock, do not

expose  this  appliance  to  rain  and  moisture.  The

apparatus  shall  not  be  exposed  to  dripping  or

splashing  and  no  objects  filled  with  liquids,  such

as vases, shall be placed on the apparatus.

DETAILED SAFETY INSTRUCTIONS:

1)  Read  these  instructions.

2)  Keep  these  instructions.

3)  Heed  all  warnings.

4)  Follow  all  instructions.

5)  Do  not  use  this  apparatus  near  water.

6)  Clean  only  with  dry  cloth.

7)  Do  not  block  any  ventilation  openings.  Install  in

accordance  with  the  manufacturer’s  instructions.

8) Do not install near any heat sources such as radiators,

heat  registers,  stoves,  or  other  apparatus  (including

amplifiers)  that  produce  heat.

9)  Do  not  defeat  the  safety  purpose  of  the  polarized  or

grounding-type  plug.  A  polarized  plug  has  two  blades

with  one  wider  than  the  other.  A  grounding  type  plug

has  two  blades  and  a  third  grounding  prong.  The  wide

blade  or  the  third  prong  are  provided  for  your  safety.  If

the  provided  plug  does  not  fit  into  your  outlet,  consult

an  electrician  for  replacement  of  the  obsolete  outlet.

10)  Protect  the  power  cord  from  being  walked  on  or

pinched  particularly  at  plugs,  convenience  receptacles,

and  the  point  where  they  exit  from  the  apparatus.

11)  Only  use  attachments/accessories  specified  by  the

manufacturer.

12)  Use  only  with  the  cart,  stand,  tripod,  bracket,  or  table

specified  by  the  manufacturer,  or  sold  with  the

apparatus. When a cart is used, use caution when moving

the  cart/apparatus  combination  to  avoid  injury  from

tip-over.

        

13)  Unplug  this  apparatus  during  lightning  storms  or

when  unused  for  long  periods  of  time.

14)  Refer  all  servicing  to  qualified  service  personnel.

Servicing  is  required  when  the  apparatus  has  been

damaged  in  any  way,  such  as  power  supply  cord  or  plug

is damaged, liquid has been spilled or objects have fallen

into  the  apparatus,  the  apparatus  has  been  exposed  to

rain  or  moisture,  does  not  operate  normally,  or  has  been

dropped.

15)  CAUTION  -  These  service  instructions  are  for  use  by

qualified  service  personnel  only.  To  reduce  the  risk  of

electric  shock  do  not  perform  any  servicing  other  than

that  contained  in  the  operation  instructions  unless  you

are  qualified  to  do  so.

Summary of Contents for 1204

Page 1: ...Version 1 0 January 2006 User s Manual XENYX 1204 1204FX...

Page 2: ...se of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third pr...

Page 3: ...o channels 7 2 2 3 Aux sends stereo channels 7 2 2 4 Routing switch solo and channel fader 7 2 3 Connector panel and main section 7 2 3 1 Aux sends 1 and 2 7 2 3 2 Aux send connectors 1 and 2 7 2 3 3...

Page 4: ...nterface transfers the stereo mix from the console directly to a computer Both the recording signal and the playback signal from the computer can be monitored at the same time In this way you can use...

Page 5: ...devices such as radiators or power amps The console is connected to the mains via the supplied cable The console meets the required safety standards Blown fuses must only be replaced by fuses of the s...

Page 6: ...fader so that the effects volume in a channel corresponds to the position of the channel fader If this were not the case the effects signal of the channel would remain audible even when the fader is t...

Page 7: ...the CLIP LED the SOLO switch and the channel fader function in the same way as the mono channels 2 3 Connector panel and main section Whereas it was useful to trace the signal flow from top to bottom...

Page 8: ...TURN 2 connectors which are routed to the main mix MAIN MIX ALT 3 4 The MAIN MIX ALT 3 4 switch routes the signal connected to STEREO AUX RETURN 2 to either main mix not pressed or submix Alt 3 4 pres...

Page 9: ...nd the stereo line inputs The solo bus is as a rule switched post fader The PAN control in the channel strip offers a constant power characteristic This means that the signal is always at a constant l...

Page 10: ...phantom power supply SERIAL NUMBER Please note the important information on the serial number given in chapter 1 3 3 3 DIGITAL EFFECTS PROCESSOR Fig 3 1 Digital effects module only 1204FX 24 BIT MULT...

Page 11: ...screws holding the mixing console side panels to fasten the 19 rack mounts 4 2 Cable connections You will need a large number of cables for the various connections to and from the console The illustra...

Page 12: ...bal 10 kW unbal Max input level 22 dBu 5 SPECIFICATIONS Main outputs Type XLR electronically balanced Impedance approx 240 W bal 120 W unbal Max output level 28 dBu Control room outputs Type 1 4 TS co...

Page 13: ...nclosed list during normal business hours BEFORE returning the product All inquiries must be accompanied by a description of the problem BEHRINGER will then issue a return authorization number 2 Subse...

Reviews: