Onyx User Manual Version 5.2
20
The configuration above will result in the unit acquiring a GPS position every hour, which will
cause all 24 GPS positions to be sent in a single SBD transmission once daily.
In-Motion Timer
The motion detection functionality can be adjusted or disabled. By default, once motion is
detected, the Onyx will continue to check for motion every two seconds until no motion is
measured for a period of several minutes.
This motion check timer can be adjusted through the ACS timer.
Example:
To set the motion check to a 10 second interval during normal mode, issue the following
command:
$timer ACS 0 10s
In-Motion Threshold
The magnitude of motion required to enter In-Motion mode can also be adjusted with the $athrs
command. The default threshold is 100. Increasing this value will make the Onyx less likely to
enter In-Motion mode
$athrs 200
Motion detection can also be disabled or enabled using the $switch command:
$switch m 0
To re-enable motion detection if it has been disabled, issue the command:
$switch m 1
Summary of Contents for Onyx
Page 1: ...Onyx User Manual Miniature Iridium Asset Tracker with Relay Function Version 5 2 May 2018 ...
Page 31: ...Appendix C Mechanical Drawings Onyx ...
Page 32: ...Onyx User Manual Version 5 2 2 Onyx I ...
Page 33: ...Onyx User Manual Version 5 2 3 Onyx R ...
Page 34: ...Onyx User Manual Version 5 2 4 Onyx M RH ...
Page 35: ...Onyx User Manual Version 5 2 5 Onyx WB ...
Page 36: ...Onyx User Manual Version 5 2 6 Onyx OEM ...
Page 37: ...Onyx User Manual Version 5 2 7 Onyx Low Voltage OEM ...
Page 39: ...Onyx User Manual Version 5 2 9 A 05 008 Onyx Onyx R Diagnostic Cable ...
Page 40: ...Onyx User Manual Version 5 2 10 A 05 063 Onyx WB Diagnostic Cable ...
Page 41: ...Onyx User Manual Version 5 2 11 A 05 064 Onyx WB Power Cable Flying Leads ...