Onyx User Manual Version 5.2
4
Mobile Terminated SBD (To Device)
To send a payload of data to your connected serial device via the Onyx-Relay, create a file with
the extension “.sbd” with its contents adhering to the following format:
$unlock 12345
$outPort X (where 'X' is the alphabetic port number of the connected device)
payload line 1
payload line 2
payload line 3
payload line 4
Again, all lines are terminated with either a carriage return, line feed, or both. The unlock line
will be a 5 digit numerical code, unique to each device. Its purpose is to prevent accidental or
malicious commands from being processed by either the Onyx-Relay, or your connected device.
When the data to be sent is compiled, normal methods of sending commands to Iridium devices
can be implemented, either through email or a web service such as XeosOnline.
All lines after the “$outPort” line will be delivered to the connected serial device the next time
the Onyx-Relay is scheduled to contact the Iridium network
.
The total message, cannot exceed
270 bytes. Upon reception of the $outPort command, the Onyx-Relay would output the following
data to the connected serial device, according to the above example:
payload line 1
payload line 2
payload line 3
payload line 4
Summary of Contents for Onyx
Page 1: ...Onyx User Manual Miniature Iridium Asset Tracker with Relay Function Version 5 2 May 2018 ...
Page 31: ...Appendix C Mechanical Drawings Onyx ...
Page 32: ...Onyx User Manual Version 5 2 2 Onyx I ...
Page 33: ...Onyx User Manual Version 5 2 3 Onyx R ...
Page 34: ...Onyx User Manual Version 5 2 4 Onyx M RH ...
Page 35: ...Onyx User Manual Version 5 2 5 Onyx WB ...
Page 36: ...Onyx User Manual Version 5 2 6 Onyx OEM ...
Page 37: ...Onyx User Manual Version 5 2 7 Onyx Low Voltage OEM ...
Page 39: ...Onyx User Manual Version 5 2 9 A 05 008 Onyx Onyx R Diagnostic Cable ...
Page 40: ...Onyx User Manual Version 5 2 10 A 05 063 Onyx WB Diagnostic Cable ...
Page 41: ...Onyx User Manual Version 5 2 11 A 05 064 Onyx WB Power Cable Flying Leads ...