background image

 

OSKER User Manual Version 3.0 

 

16 

Messages to the OSKER 

Settings 

The 

$settings

 command will return a truncated list of important OSKER settings aside from 

timers with their current values. Changing any of these values WILL impact performance. 
Greyed out sections are unused by the OSKER. 

 

Name        Default            Description 
GPS Settings (GPS) 

MxOn

 

180 

Maximum GPS session length in seconds 

MxPr

 

90 

Maximum GPS session length in poor conditions 

Tmn

 

-30 

Temperature minimum 

Vmn

 

9.000  Voltage minimum 

gBlk0

 

0,0 

GPS Blackout, unused 

gBlk1

 

0,0 

GPS Blackout, unused 

gRtQ

 

GPS retry quantity 

gRtyD

 

20 

GPS retry delay in seconds 

gFRst

 

50 

Number of GPS failures for GPS reset 

wcIC 

85 

WC Inner Percent for 

WC Warning message

 (Val = % of WC Radius) 

gBL

 

24 

Maximum saved GPS fixes 

gFQ

 

12 

Maximum GPS fixes per message 

 

 

System Settings (Sys) 

PB

 

Build 

Firmware Build 

BtP

 

Bluetooth on or off

 

BtT

 

Bluetooth Timeout in minutes 

BtN

 

Name  Bluetooth Name 

LL

 

Diagnostic Log detail level 

UC 

Code 

Unlock Code 

aes 

AES Encryption enabled yes/no 

rHr

  

Hour on which timings are based (24h UTC) 

rMn

  

SBD hour offset in minutes

 

 

 

Iridium Settings (Ird) 

iBlk0

 

0,0 

Iridium Blackout, unused 

iBlk1

 

0,0 

Iridium Blackout, unused 

iRtyQ

 

SBD Retry Quantity 

Smx

 

Maximum SBD attempts per Iridium session 

MxLn

 

330 

Maximum message length (bytes) 

iWR

 

Wait for registration with Iridium network to send data 

um 

Unsolicited messages 

 

 

 

Summary of Contents for OSKER

Page 1: ...OSKER User Manual IRIDIUM GPS SURFACE TRACKING SYSTEM Version 3 0 March 2019...

Page 2: ...or your device contact support xeostech com Version History Version No Date Description 1 0 Nov 2015 Initial document 2 0 Jun 2017 Updated magnet switch details 2 1 Apr 2018 Re formatting standardized...

Page 3: ...8 OSKER Operation 9 Using the Magnets 9 Messages From the OSKER 10 Version Type V 10 Position Message 10 Compressed Binary Position 10 ASCII Position Type P 11 Status Change Message Type S 12 Informat...

Page 4: ...he Timer Command 19 Changing the Timers 20 Watch Circle 21 Enabling the Watch Circle 21 Setting the Watch Circle 21 Example 21 Enable Inversion Events 22 Message Enable 22 Other Commands 23 Installati...

Page 5: ...ing currents oil spills or other phenomenon Users can set the Watch Circle with a radius of up to 15km to get automatic notification if any of the units travel outside of a designated area See www xeo...

Page 6: ...ve 5 unique email addresses this may vary between service providers When registering an IMEI number please provide the service provider with a temporary Xeos testing account email address This account...

Page 7: ...ill always have the IMEI of the device in the subject line regardless of its name on XeosOnline FIGURE 2 AN EXAMPLE OF A RAW IRIDIUM MESSAGE FROM A DEVICE VIA EMAIL sbdservice sbd iridium com All mess...

Page 8: ...ng the Lat Long that the body has supplied Iridium is 80 confident always 80 that the device sending the message is within a circle 2 kilometers in radius with the Lat Long given as the centre of that...

Page 9: ...minimum of 1500 messages to a full deployment battery depletion Using the Magnets A magnetic tab embedded into the side of the OSKER s enclosure keeps the device s power source disengaged from the ele...

Page 10: ...used in OSKER Position Message Typical position messages are sent in compressed binary format Message Type 10 to save on data usage and are parsed in XeosOnline If XeosOnline is not used GPS Text Shor...

Page 11: ...S Fix higher is better 37 is good Each compressed message is 26 bytes in size with an additional 11 bytes added for each additional stacked position ASCII Position Type P In ASCII position format only...

Page 12: ...other factor the follow up Iridium session will send a synopsis of the latest statistics from the device This message will always be in ASCII format regardless of message format settings and approxima...

Page 13: ...icate with the Iridium network commands will remain queued for five days Command Format CREATING THE FILE To create an SBD command open a new file in a text editor ex Notepad and save it using the sbd...

Page 14: ...added at the beginning of the message The unlock code will only be changed if the firmware is updated or if commanded via unlock XXXXX YYYYY Where XXXXX is the current code and YYYYY is the new code...

Page 15: ...ver to the right hand target list using the button Type your command s into the command box and press send Remember to include the dollar sign ahead of each command and enter each command on a separat...

Page 16: ...ry delay in seconds gFRst 50 Number of GPS failures for GPS reset wcIC 85 WC Inner Percent for WC Warning message Val of WC Radius gBL 24 Maximum saved GPS fixes gFQ 12 Maximum GPS fixes per message S...

Page 17: ...ridium Message Count The number of SBD messages queued for sending Iridium Session Count Total successful Iridium connections Iridium On Time Total successful Iridium connections on first try Iridium...

Page 18: ...after which the OSKER will enter Normal mode Normal Mode Once Start up mode has finished the OSKER will enter Normal mode Timer 0 This is the default timer mode of the OSKER and will be used if no oth...

Page 19: ...powered on or reset Timer 2 Alarm Used once the unit s watch circle is triggered Timer 4 No GPS Fix Used when the GPS module consistently fails to acquire a fix While the timers are able to be manipu...

Page 20: ...uts a practical limit on the ratio of GPS fixes to Iridium checks Regardless the method being used to communicate with the OSKER timer commands are always the same format timer SYSTEM TIMER MODE INTER...

Page 21: ...nabled the specifics of the user s circle can be implemented Setting the Watch Circle The watch circle parameters can be set by sending the setcircle command using this format setcircle Latitude Longi...

Page 22: ...y messages These message formats can be changed using the msgenable command The OSKER has the following message types available for use Message Number Message Type 0 GPS Plain Text Short 1 GPS Plain T...

Page 23: ...for the OSKER btpcycle Power cycle Bluetooth batt Show battery status settings Show all settings stats Show statistics since last powerup reset statsL Show Lifetime Statistics switch X 1 0 Switch com...

Page 24: ...ice has two GPS Iridium antenna assemblies for such events Due to this the device can be deployed inverted as well as label side up Finally most use cases will require deployment from the sea or air T...

Page 25: ...lkaline Sleep Current 100uA avg Iridium Transmit 36mA 30s avg GPS Acquisition 15 mA 30s avg Voltage 12 0 Volts nominal Capacity 2 4 Amp Hours Electronics Digital Controller Xeos IRDC 3 GPS Receiver 48...

Page 26: ...OSKER User Manual Version 3 0 26 Appendix B Engineering Diagrams...

Page 27: ...ields are not used in the OSKER GPS Text Long Readout 12251850 Date and Time MMDDHHMM S Status Type message 2019 12 25 18 50 13 Date and time adds year and second of fix 44 71441 Latitude 63 60495 Lon...

Page 28: ...Warranty is void if failure of the product has resulted from accident abuse or misapplication Any replacement product will be warranted for the remainder of the original warranty period or ninety 90...

Reviews: