OSKER User Manual Version 3.0
16
Messages to the OSKER
Settings
The
$settings
command will return a truncated list of important OSKER settings aside from
timers with their current values. Changing any of these values WILL impact performance.
Greyed out sections are unused by the OSKER.
Name Default Description
GPS Settings (GPS)
MxOn
180
Maximum GPS session length in seconds
MxPr
90
Maximum GPS session length in poor conditions
Tmn
-30
Temperature minimum
Vmn
9.000 Voltage minimum
gBlk0
0,0
GPS Blackout, unused
gBlk1
0,0
GPS Blackout, unused
gRtQ
2
GPS retry quantity
gRtyD
20
GPS retry delay in seconds
gFRst
50
Number of GPS failures for GPS reset
wcIC
85
WC Inner Percent for
WC Warning message
(Val = % of WC Radius)
gBL
24
Maximum saved GPS fixes
gFQ
12
Maximum GPS fixes per message
System Settings (Sys)
PB
Build
Firmware Build
BtP
Y
Bluetooth on or off
BtT
5
Bluetooth Timeout in minutes
BtN
Name Bluetooth Name
LL
0
Diagnostic Log detail level
UC
Code
Unlock Code
aes
N
AES Encryption enabled yes/no
rHr
0
Hour on which timings are based (24h UTC)
rMn
2
SBD hour offset in minutes
Iridium Settings (Ird)
iBlk0
0,0
Iridium Blackout, unused
iBlk1
0,0
Iridium Blackout, unused
iRtyQ
2
SBD Retry Quantity
Smx
8
Maximum SBD attempts per Iridium session
MxLn
330
Maximum message length (bytes)
iWR
Y
Wait for registration with Iridium network to send data
um
3
Unsolicited messages