Apollo-X User Manual Version 0.9
32
Commands Summary
Below is a quick summary of commonly used commands that can be sent via Iridium or
Bluetooth to acquire additional information, or configure the Apollo-X. Remember to add the
$
symbol ahead of any commands.
Command
Parameters
Description
timer
---, or component Display the entire configuration of all intervals of all systems,
in all modes.
switch
X 1/0
Switch component X on/off. No parameter lists all components
and their states
settings
---
Show all settings and thresholds
status
---
Returns the timer mode the device is currently using
unlock
---
Returns the unlock code of the device
sysInf
---
GPS and Iridium pass/fail
summary, outputs “I” message
iss
---
Display Iridium performance metrics
viewsensor
---
Display latest sensor readings
lightthresh
X
Set the threshold where the environment is dark (higher
threshold is more likely to be dark)
wsthresh
X
Set the threshold where the device shows as submerged
(higher threshold is more likely to be submerged)
batterythresh
X
Set the value the loaded voltage has to be lower than to
trigger Low Battery mode, in
millivolts
tiltorientation
X
Set the angle at which the device determines it is inverted (See
StrFlshUW
1/0
Enable strobe flashing while underwater (1 = Flash)
btPwr
1
Bluetooth power on, for two minutes
btName
NAME
Set the Bluetooth name for the device. No spaces allowed.
ver
---
Show firmware/hardware version, product type, IMEI etc.
Equal to the initial message after a reset.
FactoryDefaults
---
Reset all to settings to defaults. The device does
not
reset.
ResetNow
---
Restarts the system. The effect is the same as restarting via
the magnet