Apollo-X User Manual Version 0.9
38
Appendix B: Technical Specifications
Electrical
X7
X3
X1
XRH
Supply Range
(VDC)
6
–
20
6 - 20
2.7 - 5
6 - 28
Batteries
Energizer
Industrial LR20
D-Cell (7)
Saft LSH20
D-Cell (3)
Saft LSH20
D-Cell (1)
User Defined,
Standard
packs avail.
Battery Capacity
(Amp hours)
18.5
13
13
User Defined
Voltage Input
(VDC)
10.5 Nominal
10.8 Nominal
3.6 Nominal
User Defined
Idle Current
(µW),
Relay (mW)
480
480
400
480
Underwater
Current (µW)
0.3
0.3
0.175
0.3
Strobe Flash
(mW/Flash,
50ms)
3600
3600
3100
3600
GPS Current (30s
average, mW)
204
204
180
204
Iridium Tx (30s
average, mW)
800
800
1200
800
Iridium Tx Peak
(A)
1.5
1.5
1.5
1.5
Bluetooth
Connected (mW)
40
40
36
40
Only the Saft LSH20 has the ability to source enough current to supply peaks in Iridium
transmissions in lithium models, and is therefore required in these applications.
Batteries should be removed if device is entering storage.