background image

All measurements were made on products performing within established operating specifications and received
recommended maintenance procedures.  Xerox certifies that this product meets or exceeds the applicable standards for
safety and emissions.

http://www.xerox.com:80/environment.html

PRODUCT:  2300

PSDS No. 0607

Section V - Emission/Exposure Information*

Light Source

Long term viewing of exposure lamp may be uncomfortable but not harmful.

Electromagnetic Emissions

US

FCC:   Class A

Canada

DOC:  Class A

Germany

VDE:   Class B

Audible Noise

TLV

Running:

59.5 dB (A)

85.0 dB (A)

Standby:

46.5 dB (A)

Impulse:

74.0 dB (A)

Ozone

TLV

92  ug/min

0.1 ppm

0.009 ppm (TWA)
0.024 ppm (Peak)

Concentration Based on Customer Simulation Model:
Daily Copy Volume

270 copies / 7.84 hours

Room Size

5.0 m

3

1/2 Air Room Change per Hour

Dust TLV

0.024 - 0.31 mg/m

3

10 mg/m

3

Selenium

TLV

< 0.035 - 0.05 ug/m

3

200 ug/m

3

Arsenic

PEL

< 0.022 ug/m

3

10 ug/m

3

Nitrogen Dioxide

TLV

< 0.04 ppm

3 ppm

TLV

 (Threshold Limit Value) and

 PEL

 (Permissible Exposure Level) respectively set by American Conference of

Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are
considered maximum exposure permitted to ensure no health hazard.  

TWA

 (Time Weighted Average) for a normal

eight hour workday.

07/07/97