All measurements were made on products performing within established operating specifications and received
recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for
safety and emissions.
http://www.xerox.com:80/environment.html
PRODUCT: 2300
PSDS No. 0607
Section V - Emission/Exposure Information*
Light Source
Long term viewing of exposure lamp may be uncomfortable but not harmful.
Electromagnetic Emissions
US
FCC: Class A
Canada
DOC: Class A
Germany
VDE: Class B
Audible Noise
TLV
Running:
59.5 dB (A)
85.0 dB (A)
Standby:
46.5 dB (A)
Impulse:
74.0 dB (A)
Ozone
TLV
92 ug/min
0.1 ppm
0.009 ppm (TWA)
0.024 ppm (Peak)
Concentration Based on Customer Simulation Model:
Daily Copy Volume
270 copies / 7.84 hours
Room Size
5.0 m
3
1/2 Air Room Change per Hour
Dust TLV
0.024 - 0.31 mg/m
3
10 mg/m
3
Selenium
TLV
< 0.035 - 0.05 ug/m
3
200 ug/m
3
Arsenic
PEL
< 0.022 ug/m
3
10 ug/m
3
Nitrogen Dioxide
TLV
< 0.04 ppm
3 ppm
*
TLV
(Threshold Limit Value) and
PEL
(Permissible Exposure Level) respectively set by American Conference of
Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are
considered maximum exposure permitted to ensure no health hazard.
TWA
(Time Weighted Average) for a normal
eight hour workday.
07/07/97