background image

AccXES Version 10.2 Installation Instructions 

 

Warning: If you have an HFT controller with AccXES 8.0 or 8.5, upgrading to AccXES 9.0 will 
cause you to lose the following Data Format Interpreters (DFI): 
 

• VCGL  
• Versatec Raster (VRF & VDS)  

• CGM  

 

These DFIs are no longer part of the standard system. A feature key is necessary to enable them. 
The DFI Feature Keys can be purchased through Xerox Sales or an Authorized Reseller. See Step 
1 to determine if you have the appropriate controller.  

 

Note: For the Xerox 6050 and 6030 Wide Format products, one must activate the AccXES print server by 

downloading the appropriate print server feature key

.  

 

Warning: If the current AccXES Version is 8.0 or lower, upgrading to AccXES 9.0 will eliminate all existing 
feature keys. Once installation is complete, you will need to reinstall your feature keys. If you are currently 

at AccXES 9.0 or greater, your feature keys will be retained.  
 

Step 1 

Determine your Hardware Configuration  

There are distinct versions of firmware for each controller hardware platform. Firmware is available for the 
hardware platforms as indicated below. Your hardware platform can be determined by examining the 

printer configuration test print or serial number (found on the AccXES controller unit). Note your hardware 
version. Note: Use the HFT firmware as this will be the correct downloadable binary for PUN controllers.  

 

Controller 

CPU from Test Print 

Serial Number 

PUN RTT-MPC 

7410 

PUN-XXXXX 

HFT RTT-MPC 

7410 

HFT-XXXXX 

CNG 

PPC740 – 200 

CNG-XXXXX 

KLF 

PPC740 – 200 

KLF-XXXXX 

N5T 

PPC740 – 200 

N5T-XXXXX 

EV4 MPC8240-250 

EV4-XXXXX 

 

Step 2 

Release Notes  

Download, print, and read the AccXES release notes (pdf format). The release notes can be found in the 
documentation section or by using the ‘See Also’ link.  

 

Step 3 

Check Disk Size and RAM Requirements  

Consult the Recommended Configurations Chart in the AccXES Release Notes to confirm that your 
Controller has the required disk size and RAM needed for the AccXES upgrade. This chart can be found in 

the documentation section or by using the ‘See Also’ link. 
 

Step 4

 

Job Accounting Migration (if applicable)  

Warning: As a precaution, save your Job Accounting Data prior to upgrading. If you have AccXES 7.5 or 
greater and are using Job Accounting, use the Account Management Tool (AMT) to collect existing Job 

Based Accounting Data from the AccXES Controller / Printer. If you have AccXES 6.1 or lower and are using 
job accounting, please read the Job Accounting Migration document (found in the Documentation section) 

which describes the migration process from the legacy accounting system to the new Job Based Accounting 
system. Legacy Job Log files are deleted when upgrading to AccXES 7.5 or greater. Use the Web Printer 

Manager Tool, Scanner UI or ACT to retrieve/store your legacy data prior to upgrading AccXES.  

 

 

Reviews: