October 2012
4-53
ColorQube 8570/8870 Service Manual
REP 2.22, REP 2.24
Repairs and Adjustments
Xerox Internal Use Only - Revised, 3rd Revision
9.
Pull the X-Axis Bias Spring Hook out.
10. Disconnect the wiring harness connector on the X-Axis Bias Spring Hook.
Figure 3 Removing the X-Axis Bias Spring Hook
REP 2.24 X-Axis Bias Spring
Parts List on
PL 2.1 Item 24
Removal
CAUTION
The X-Axis Bias Spring is in close proximity to the Drum Assembly. Use care to not damage
the Drum while servicing the Spring.
1.
Remove the Control Panel Cover (
REP 1.5
).
2.
Remove the Left Side Cover (
REP 1.10
).
3.
Remove the Right Side Cover (
REP 1.11
).
4.
Remove the Exit Cover (
REP 1.7
)
5.
Remove the Ink Loader (
REP 1.8
).
6.
Remove the Funnel Cap (
REP 2.1
).
7.
Remove the Jetstack Cap (
REP 2.2
).
8.
Remove the Printhead (
REP 2.3
).
9.
Remove the X-Axis Bias Spring using a spring hook or pliers.
Figure 1 Removing the X-Axis Bias Spring
Replacement
DO NOT rotate the spring more than one-quarter turn. Perform the Homing the Printhead For-
ward to Print Position procedure (
ADJ 1.2
) and Process Drive Alignment procedure (
ADJ 1.3
)
before restoring printer power.