REP 3.13
Revised, 3rd Revision - Xerox Internal Use Only
Repairs and Adjustments
7.
Open the Exit Module.
8.
Open the Lower Exit Guide Assembly.
9.
Disconnect the Drum Temperature Sensor wiring harness connector
P/J130
.
Figure 3 Disconnecting the Drum Temperature Sensor Wiring Harness Connector
10. Remove the 4 screws (metal, T-20) that secure the Exit Module.
11.
Lift the Exit Module from the chassis.
Figure 4 Removing the Exit Module
Replacement
Seat the Exit Module on the chassis. Torque the 4 screws to 12 in.-lbs and perform Wiper
Blade Alignment procedure (