General Troubleshooting
LED Information
Electronics Module DC Power LEDs
The Electronics Module has 3 Power LEDs to indicate power.
•
+3.3V Sleep LED (green)
•
+3.3V LED (green)
•
+50V LED (red)
The +50V LED goes off when the printer is turned off, a short circuit or overload is present on
the +50V or -50V supplies, or when the printer goes into a deep Standby mode (15-20 sec-
onds). The +3.3V LED goes off when the printer is turned off or enters Sleep Mode (time
according to user preference).
The +50 V is on at the following stages:
•
During mechanical initialization - bringing up the printer
•
The printer is printing.
•
The printer is recovering from jam.
•
Drum slew - managing Drum Thermals
•
Drum Maintenance
•
Any Tray is open.
•
Any Door is open.
•
The printer is melting ink.
•
The printer is performing a head maintenance cycle.
•
The Printhead is tilting.
The 50 volts will be off when the printer is idle and not performing any of the listed tasks. The
+50V LED may be dim or extinguished when 50V is off.
The +50V will not be on at all time. The +50V can be Off when the printer is at Ready mode.
Figure 2 Power Control Board LEDs