6/02
6-27
DC1632/2240
General Procedures and Information
Prelaunch Training/Review
746--xxx Zero Transfer NVM List
744-004
STS-2 High-TEMP-Not-Ready TEMP
220
150~250
(1 bit=1 deg.C)
Once the STS-2 reaches High Temperature Not-Ready Temperature, the Fuser is moved to sagging status.
This is because when continuous Run is performed for A5SEF and below, Temperature Distribution Control
would fail.
744-005
STS-1 Ready Temperature
150
100~150
(1 bit=1 deg.C)
For an appropriate distribution of [Ready to copy] Temperature.
744-006
STS-2 Ready Temperature
127
100~150
(1 bit=1 deg.C)
For an appropriate distribution of [Ready to copy] Temperature.
744-007
STS-1 Stand-by Temperature
160
100~200
(1 bit=1 deg.C)
For an appropriate distribution of Standby Temperature.
744-008
STS-2 Stand-by Temperature
160
100~200
(1 bit=1 deg.C)
For an appropriate distribution of Standby Temperature.
744-051
Environment Temperature Correction
3
0~5
Environment dependent correction coefficient for level of fusing. Temperature AD value shift amount when the
environment temperature varies 1 Degrees Celsius from 20 Degrees Celsius. Corrects the target temperature
of Ready temperature/Standby temperature/RUN. Both STS-1 and STS-2 have the same temperature. Cor-
rects between 10 ~ 20 Degrees Celsius. Correction is not performed outside this range. 0 = No 1 = 0.2
Degrees Celsius/Environment Temperature (Maximum 2 Degrees Celsius) 2 = 0.4 Degrees Celsius/Environ-
ment Temperature (Maximum 4 Degrees Celsius) 3 = 0.6 Degrees Celsius/Environment Temperature (Maxi-
mum 6 Degrees Celsius) 4 = 0.8 Degrees Celsius/Environment Temperature (Maximum 8 Degrees Celsius) 5 =
1.0 Degrees Celsius/Environment Temperature (Maximum 10 Degrees Celsius)
744-052
STS-1 Low TEMP Not-Ready TEMP
125
100~150
(1 bit=1 deg.C)
Once the STS-1 reaches Low Temperature Not-Ready Temperature, the Fuser is moved to sagging status to
avoid poor fusing.
744-053
STS-2 Low TEMP Not-Ready TEMP
125
100~150
(1 bit=1 deg.C)
Once the STS-2 reaches Low Temperature Not-Ready Temperature, the Fuser is moved to sagging status to
avoid poor fusing.
744-054
HFSI Counter Index
0
0~5
For HFSI Counter Symmetry
744-085
Plain Paper S Setting Temperature
5
0~5
0 = Light Weight paper (55~63gsm) 1 = Plain paper (64~70gsm) 2 = Plain paper (71~80gsm) 3 = Bond
(81~89gsm) 4 = Bond (90~98gsm) 5 = Bond (99~105gsm)
744-196
Plain Paper S Setting Temperature
2
0~2
0 = Light Weight paper (55~63gsm) 1 = Plain paper (64~80gsm) 2 = Bond (81~105gsm)
744-197
104 OHP Pitch Adjustment Value
0
0~10
(1 count=1 pitch)
OHP Blocking Measures; It prevents OHP Blocking by lowering the PPM with increase of Pitch. A4LEF =
PPM=66/(4+NVM value) A4SEF = PPM=66/(5+NMV value)
744-198
52 OHP Pitch Adjustment Value
1
0~10
(1 count=1 pitch)
OHP Blocking Measures; It prevents OHP Blocking by lowering the PPM with increase of Pitch. A4LEF =
PPM=33/(3+NVM value) A4SEF = PPM=33/(4+NVM value)
Table 9 Chain 744
Chain-Link
Name
Default
Range
Description
Table 10 Chain 746
Chain-Link
Name
Default
Range
Description
746-006
2nd Resistance detection calculation
results
245
102~921
(1bit= -4.888V)
Measures the resistance of the Secondary Transfer part composed of 2nd BTR and Backup Roll at printable -
1000V and display the voltage at Secondary Transfer corresponding that resistance. Secondary Transfer Volt-
age=245x-4.888=-1200V (Display range = 500V~- 4500V)
746-007
Final output value (Voltage value)
17
0~1023
(1bit= 1M Ohm)
Measures and displays the resistance of the Secondary Transfer part composed of 2nd BTR and Backup Roll at
printable -1000V. (Display range = 0~1023M Ohm)
746-009
Calculation results of Absolute Humidity 9
0~200
Displays the absolute humidity calculated from the relative humidity and relative temperature. (Absolute Humid-
ity=(5.375-0.077*Temp0.027*Temperature 2)*Humidity/100)
Summary of Contents for DocuColor 1632
Page 4: ...6 02 2 DC1632 2240 Prelaunch Training Review Introduction ...
Page 9: ...6 02 vii DC1632 2240 Introduction Prelaunch Training Review Translated Warnings ...
Page 22: ...6 02 xx DC1632 2240 Prelaunch Training Review Introduction ...
Page 24: ...6 02 1 2 DC1632 2240 Prelaunch Training Review Service Call Procedures ...
Page 38: ...6 02 2 8 DC1632 2240 Prelaunch Training Review Status Indicator RAPs ...
Page 44: ...6 02 2 14 DC1632 2240 1 306 Prelaunch Training Review Status Indicator RAPs ...
Page 452: ...6 02 3 2 DC1632 2240 Prelaunch Training Review Image Quality ...
Page 474: ...6 02 3 24 DC1632 2240 Image Quality Specifications Prelaunch Training Review Image Quality ...
Page 486: ...6 02 4 12 DC1632 2240 REP 1 13 Prelaunch Training Review Repairs and Adjustments ...
Page 490: ...6 02 4 16 DC1632 2240 REP 4 4 Prelaunch Training Review Repairs and Adjustments ...
Page 514: ...6 02 4 40 DC1632 2240 REP 5 19 Prelaunch Training Review Repairs and Adjustments ...
Page 568: ...6 02 4 94 DC1632 2240 REP 9 27 Prelaunch Training Review Repairs and Adjustments ...
Page 572: ...6 02 4 98 DC1632 2240 REP 10 3 Prelaunch Training Review Repairs and Adjustments ...
Page 616: ...6 02 4 142 DC1632 2240 REP 12 20 Prelaunch Training Review Repairs and Adjustments ...
Page 624: ...6 02 4 150 DC1632 2240 REP 14 11 REP 14 12 Prelaunch Training Review Repairs and Adjustments ...
Page 638: ...6 02 4 164 DC1632 2240 ADJ 6 1 Prelaunch Training Review Repairs and Adjustments ...
Page 660: ...6 02 4 186 DC1632 2240 ADJ 12 1 Prelaunch Training Review Repairs and Adjustments ...
Page 766: ...6 02 6 2 DC1632 2240 Prelaunch Training Review General Procedures and Information ...
Page 864: ...6 02 7 2 DC1632 2240 Prelaunch Training Review Wiring Data ...
Page 904: ...6 02 7 42 DC1632 2240 Plug Jack Locations Prelaunch Training Review Wiring Data ...
Page 906: ...6 02 7 44 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data Figure 2 ACN Wirenet ...
Page 907: ...6 02 7 45 DC1632 2240 Wirenets Wiring Data Prelaunch Training Review Figure 3 3 3VDC Wirenet ...
Page 917: ...6 02 7 55 DC1632 2240 Wirenets Wiring Data Prelaunch Training Review Figure 13 24VDC 1 of 4 ...
Page 918: ...6 02 7 56 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data Figure 14 24VDC 2 of 4 ...
Page 919: ...6 02 7 57 DC1632 2240 Wirenets Wiring Data Prelaunch Training Review Figure 15 24VDC 3 of 4 ...
Page 920: ...6 02 7 58 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data Figure 16 24VDC 4 of 4 ...
Page 921: ...6 02 7 59 DC1632 2240 Wirenets Wiring Data Prelaunch Training Review Figure 17 24V RTN 1 of 4 ...
Page 922: ...6 02 7 60 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data Figure 18 24V RTN 2 of 4 ...
Page 926: ...6 02 7 64 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data Figure 22 IIT 24V RTN ...
Page 928: ...6 02 7 66 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data Figure 24 DADF 5V RTN ...
Page 936: ...6 02 7 74 DC1632 2240 Wirenets Prelaunch Training Review Wiring Data ...
Page 939: ...6 02 7 77 DC1632 2240 Chain 01 Wiring Data Prelaunch Training Review Figure 3 LVPS Control ...
Page 946: ...6 02 7 84 DC1632 2240 Chain 01 Prelaunch Training Review Wiring Data Figure 10 Monitoring ...
Page 948: ...6 02 7 86 DC1632 2240 Chain 02 Prelaunch Training Review Wiring Data Figure 2 LCD Control ...
Page 955: ...6 02 7 93 DC1632 2240 Chain 03 Wiring Data Prelaunch Training Review Figure 7 PWS Interface ...
Page 956: ...6 02 7 94 DC1632 2240 Chain 03 Prelaunch Training Review Wiring Data Figure 8 Billing ...
Page 957: ...6 02 7 95 DC1632 2240 Chain 03 Wiring Data Prelaunch Training Review Figure 9 Monitoring ...
Page 969: ...6 02 7 107 DC1632 2240 Chain 06 Wiring Data Prelaunch Training Review Figure 2 Image Input ...
Page 1001: ...6 02 7 139 DC1632 2240 Chain 08 Wiring Data Prelaunch Training Review Figure 5 Registration ...
Page 1002: ...6 02 7 140 DC1632 2240 Chain 08 Prelaunch Training Review Wiring Data Figure 6 Monitoring ...
Page 1012: ...6 02 7 150 DC1632 2240 Chain 09 Prelaunch Training Review Wiring Data Figure 10 Development Y ...
Page 1013: ...6 02 7 151 DC1632 2240 Chain 09 Wiring Data Prelaunch Training Review Figure 11 Development M ...
Page 1014: ...6 02 7 152 DC1632 2240 Chain 09 Prelaunch Training Review Wiring Data Figure 12 Development C ...
Page 1029: ...6 02 7 167 DC1632 2240 Chain 09 Wiring Data Prelaunch Training Review Figure 27 Stripping ...
Page 1032: ...6 02 7 170 DC1632 2240 Chain 09 Prelaunch Training Review Wiring Data Figure 30 IBT Cleaning ...
Page 1042: ...6 02 7 180 DC1632 2240 Chain 10 Prelaunch Training Review Wiring Data Figure 3 Fusing ...
Page 1046: ...6 02 7 184 DC1632 2240 Chain 10 Prelaunch Training Review Wiring Data Figure 7 Duplex Drive ...
Page 1047: ...6 02 7 185 DC1632 2240 Chain 10 Wiring Data Prelaunch Training Review Figure 8 Monitoring ...
Page 1055: ...6 02 7 193 DC1632 2240 Chain 12 Wiring Data Prelaunch Training Review Figure 8 Staple Control ...
Page 1056: ...6 02 7 194 DC1632 2240 Chain 12 Prelaunch Training Review Wiring Data Figure 9 Set Eject ...