Administrative functions in the Setup menu
Densitometer calibration is based on a set of density measurements and a series of
target density values for specific color patches. Calibration compensates for the
difference between measured values and target values. A choice of calibration targets
allows you to prepare your DocuColor 40 CP for the type of job you will be printing
to it.
Normally you begin calibration by specifying a standard target to use with measure-
ments that you took or measurements that you previously stored on the
DocuColor 40 CP. You can also specify an alternative target to be used with the cur-
rent measurements. You don’t need new measurements to calibrate with an alternative
target. When you apply or overwrite calibration, the currently specified target is used
with the latest measurements on the server.
T
O
PREPARE
FOR
CALIBRATION
:
1.
If this is the first time you are setting up the DocuColor 40 CP, complete Server Setup,
Network Setup, and Printer Setup before you perform a calibration. Save Setup
changes and boot up to Idle.
2.
When the DocuColor 40 CP is at Idle, turn the power switch off.
3.
Plug the AC adapter for the scanner into an outlet.
4.
Connect the scanner to the SCSI connector of the DocuColor 40 CP. This is the port to
the left of the power switch on the DocuColor 40 CP when viewed from the rear.
5.
Turn on the DocuColor 40 CP.
6.
When the Setup message appears, press any key.
7.
Scroll to the second screen of the main Setup menu and choose Calibration.
8.
Choose Set Up Calibration, and choose a calibration method.
PS Setup
Color Setup
Job Log Setup
Calibration
Setup
Exit Calibration
Set Up Calibraton
Calibrate
Remove Calibration
Calibration