RAP 2.1 Blank Control Panel
Display
WARNING
Improper connection of the grounding
conductor can result in the risk of electrical
shock. The following must be observed:
•
Never use a ground adapter plug to
connect the terminal to a power source
which does not have a ground
connection.
•
Never attempt any maintenance function
which is not specifically called out in the
service procedures.
•
Never remove any covers which are
fastened with screws, unless so
instructed in the service procedures.
CAUTION
If any of the voltage measurements are not as
specified in the following steps, the cause
must be corrected. Caution the customer not
to connect the terminal to the wall outlet.
Advise the customer that a licensed electrician
must correct the wiring. Do not attempt to
correct the wiring yourself. If you later find
the condition has not been corrected, inform
your manager in writing of the improper
wiring.
1. Perform the following line voltage check.
a.
Disconnect the power cord from the
wall outlet.
b.
USO only (Figure 1). Perform the
following:
•
Measure the AC voltage between
AC Hot and Neutral. Meter =
104 to 127 VAC.
•
Measure the AC voltage between
the AC Neutral and GND. Meter
= less than 3 VAC.
RX, UK Only (Figure 2). Perform the
following:
•
Measure the AC voltage between
live and neutral and between live
and earth. Meter = 216 to 264
VAC.
•
Measure the AC voltage between
Neutral and Earth. Meter = less
than 3 VAC.
RX, Europe Only (Figure 3). Perform
the following:
•
Measure the AC voltage between
supply pins. Meter = 196 to 244
VAC.
•
Measure the AC voltage between
one supply pin and earth.
Meter = 196 to 244 VAC.
•
Measure the AC voltage between
second supply pin and earth.
Meter = 3 VAC or less.
The voltages are correct.
Y
N
|
Inform the customer of
insufficient voltage (or improper
wiring).
Figure 1. USO Wall Outlet
AC Hot
(ACH)
GND
AC Neutral
(ACN)
USO
7033-100
Figure 2. RX UK Wall Outlet
RX Only
7033-101
Live
Earth
Neutral
Figure 3. RX Europe Wall Outlet
7033-102
Earth
Supply pins
RX Only
8/91
Telecopier 7032 / 7033 Service Manual
2-15
RAP 2.1
www.printcopy.info
www.printcopy.info
Summary of Contents for Telecopier 7032
Page 44: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 59: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 150: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 155: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 157: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 158: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 159: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 160: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 161: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 167: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 168: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 169: ...www printcopy info w w w p r i n t c o p y i n f o...
Page 172: ...www printcopy info w w w p r i n t c o p y i n f o...