BUS Updated 12/2011
07/2011
3-21
WorkCentre 5335 Family Service Documentation
Image Quality
Initial Issue
IQS6 Skew Specification
Procedure
Use Side A of the Standard Test Pattern.
Skew must be within the following ranges (with respect to each other) at the two 10 mm refer-
ence lines shown (
Figure 1
).
Figure 1 Skew
Table 1 Specification of Skew
Configuration
Range
Platen (Simplex)
+/-1.42
Platen (Duplex)
+/-1.87
Platen (MPT)
+/-1.78
DADF (Simplex)
+/-2.04
DADF (Duplex)
+/-2.40