BUS Updated 12/2011
07/2011
4-8
WorkCentre 5335 Family Service Documentation
REP 3.4, REP 3.5
Initial Issue
Repairs & Adjustments
NOTE: The AC Driver PWB screws (8) have a different thread than the other screws,
keep them with the PWB for re-installation.
5.
Remove the screws (3) from the bottom of the panel (
Figure 3
).
Figure 3 Removing Screws
6.
Remove the AC Driver PWB screws (5) from the front of the panel (
Figure 4
).
Figure 4 Removing Screws
Replacement
1.
To reinstall, carry out the removal steps in reverse order.
REP 3.5 MCU PWB
Parts List on
PL 18.2
Removal
CAUTION
ESD procedures must be used when removing or replacing PWBs. Damage to electrical com-
ponents is likely if static discharge reaches components.
Always wear a wrist strap to protect electrical parts from static damage. If a wrist strap is not
available, touch some metallic parts to discharge the static electricity before servicing.
CAUTION
A loss of serialization and billing data will occur, and disable the machine, if both the ESS PWB
with EPROM and the MCU PWB with EPROM are replaced at the same time.
1.
Switch off the power and disconnect the power cord.
2.
Remove the following covers (
Figure 1
).
a.
Pull off the ESS Cap Cover.
b.
ESS Cover (2 Screws).
c.
Left Rear Middle Cover (2 Screws).
d.
Rear Lower Cover (3 Screws).
Figure 1 Removing Covers
6
a
b
c
d