BUS Updated 12/2011
07/2011
4-20
WorkCentre 5335 Family Service Documentation
REP 5.7, REP 5.8
Initial Issue
Repairs & Adjustments
Figure 4 Ground Plate Alignment
REP 5.8 Right Counter Balance
Parts List on
PL 51.3
Removal
CAUTION
Left/Right Counter Balance is identified by its spring pressure.
•
Left Counter Balance: strong spring pressure
•
Right Counter Balance: weak spring pressure
1.
Switch off the power and disconnect the power cord.
2.
Remove the DADF Rear Cover. (
REP 5.4
)
3.
Remove the DADF. (
REP 5.1
)
4.
Take note of the graduation of the scale. (
Figure 1
)
Figure 1 Graduation Scale Marks
5.
Remove the Right Counter Balance. (
Figure 2
)
(1) Remove the self-tapping screws (Large: x3).
(2) Remove the screw (Small: x1) and remove the Ground Wire.
(3) Remove the right Counter Balance.