BUS Updated 12/2011
07/2011
6-22
WorkCentre 5335 Family Service Documentation
Component Control
Initial Issue
General Procedures & Information
Table 4 Output Component Control Codes - Integrated Office Finisher
Chain-Link
Component
Description
Time-out
conflicts
012-013
Sub Paddle Solenoid
Sub Paddle rotation
660ms
012-014
012-014
Sub Paddle Rotation
Sub Paddle makes one rotation.
(Rotates Transport Motor FORWARD at the same time as Sub Paddle Solenoid turns ON.)
Mot: 3162
Sol: 660ms
012-013
012-095
012-096
012-097
012-017
Set Clamp Motor
Set Clamp Motor rotates forward.
250 pulses
012-061
012-020
Front Tamper Mot Low
Front
Front Tamper moves to Front at low speed.
100 pulses
012-021
012-022
012-023
012-024
012-025
012-021
Front Tamper Mot Mid-
dle Front
Front Tamper moves to Front at medium speed.
100 pulses
012-020
012-022
012-023
012-024
012-025
012-022
Front Tamper Mot
High Front
Front Tamper moves to Front at high speed.
100 pulses
012-020
012-021
012-023
012-024
012-025
012-023
Front Tamper Mot Low
Rear
Front Tamper moves to Rear at low speed.
100 pulses
012-020
012-021
012-022
012-024
012-025
012-024
Front Tamper Mot Mid-
dle Rear
Front Tamper moves to Rear at medium speed.
100 pulses
012-020
012-021
012-022
012-023
012-025
012-025
Front Tamper Mot
High Rear
Front Tamper moves to Rear at high speed.
100 pulses
012-020
012-021
012-022
012-023
012-024
012-026
Rear Tamper Mot Low
Front
Rear Tamper moves to Front at low speed.
100 pulses
012-027
012-028
012-029
012-030
012-031