WorkCentre 5335 Family Service Documentation
016-328, 016-330 Memory Diag Fail-1 RAP
Status Indicator RAPs
Initial Issue
016-328 Cont-MCU Cable Connection Fail RAP
The controller has detected a failure at its cable connection with the MCU.
Procedure
Turn the power OFF and ON.
If the problem persists, perform the following:
1.
Check the connection of the cable between the controller and MCU.
2.
Replace the cable.
016-330 Memory Diag Fail-1 RAP
BSD-ON:
BSD 16.1 - ESS
Cont SystemMemory Diag Fail-1. Capacity of Slot1 loaded memory is out of spec.
Procedure
•
Power Off/On.
•
Check the sw version of the controller sw - update if required
•
Remove/insert ESS RAM DIMM.
•
Replace ESS RAM DIMM (
PL 35.2
).
•
Replace ESS PWB (
PL 35.2
).