BUS Updated 12/2011
07/2011
2-173
WorkCentre 5335 Family Service Documentation
016-378, 016-379
Status Indicator RAPs
Initial Issue
016-378 Cont HDD FileSystem Fail-G RAP
BSD-ON:
BSD 16.1 - ESS
Boot Diag detected a logic error with HDD (Partition G).
Procedure
Perform the following:
1.
Power OFF then ON.
2.
Initialize the HDD
Initialize Hard Disk
.
016-379 Cont HDD FileSystem Fail-H RAP
BSD-ON:
BSD 16.1 - ESS
Boot Diag detected a logic error with HDD (Partition H).
Procedure
Perform the following:
1.
Power OFF then ON.
2.
Initialize the HDD
Initialize Hard Disk
.