WorkCentre 5335 Family Service Documentation
024-374, 024-375
Status Indicator RAPs
Initial Issue
024-374 Registration Con PLL Parameter Fail RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. RegiCon adjustment value setting error detected by Controller (Incorrect
parameter instruction). Incorrect color registration adjustment value is sent from the IOT.
Procedure
•
Turn the power OFF then ON.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace MCU PWB (
PL 18.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS & MCU)
024-375 IOT-ESS Communication Fail 24 RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. DLL receiving error detected by Controller (Incorrect parameter instruction).
An illegal instruction for IOT Port No., Timeout Time, or Pointer was detected.
Procedure
•
Turn the power OFF then ON.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace MCU PWB (
PL 18.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS & MCU)