Status Indicator RAPs
Initial Issue
027-745 Template Address Server RAP
The DNS Server address is not set during address resolution.
Initial Actions
Power Off/On
Procedure
•
Set the DNS address. Check the Job Template Pool Server address using IP address.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)
027-746 Job Template Pool Server RAP
The port of the protocol specified in Job Template Pool Server settings is not running.
Procedure
•
Start up the port of the protocol (FTP client or SMB) specified in Job Template Pool Server
settings.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)