BUS Updated 12/2011
07/2011
2-605
WorkCentre 5335 Family Service Documentation
034-715, 034-716
Status Indicator RAPs
Initial Issue
034-715 Line Disconnected-Timeout 3082 RAP
BSD-ON:
BSD 34.1 - FAX
There is a wait release complete time-out.
Procedure
•
Check the remote machine settings and line status, then perform the operation again.
•
Check the Fax line connection (telephone line).
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWBs in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the FAX PWB (
PL 18.5
).
034-716 Connection Timeout (T313) RAP
BSD-ON:
BSD 34.1 - FAX
There is a connection time-out.
Procedure
•
Check the self-terminal status and line status, then perform the operation again.
•
Check the Fax line connection (telephone line).
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWBs in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the FAX PWB (
PL 18.5
).