BUS Updated 12/2011
07/2011
2-845
WorkCentre 5335 Family Service Documentation
102-319, 102-356
Status Indicator RAPs
Initial Issue
102-319 Dongle NVM List Setting Fault
Initial Actions
Switch the Power Off then On.
Connect the Dongle to the Front panel USB port and retry
Verify that the correct Dongle is present
Procedure
Order new (correct) Dongle. If this does not resolve the problem, replace the ESS PWB (
PL
35.2
).
102-356 EWS Soft Fail RAP
Fatal error related to the EWS. A problem occurred during software processing, and process-
ing could no longer continue.
Procedure
•
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete)
•
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
–
SNTP
–
NetWare
–
Salutation IO
–
SMB
–
Port 9100
–
USB
–
lpd
–
FTP Serv
–
MailIO
–
IPP
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the HDD, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Reinstall the latest version of the ESS software (
GP 16
).
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
•
Perform
GP 14
- - only the first three parts - make sure to follow sequence and heed cau-
tions
•
Replace HDD (
PL 35.3
)