BUS Updated 12/2011
07/2011
2-854
WorkCentre 5335 Family Service Documentation
116-323, 116-324
Initial Issue
Status Indicator RAPs
116-323 ESS NVRAM R/W Check RAP
An error is detected during the ESS PWB NVM Read/Write Check.
Initial Actions
Power Off/On
Procedure
1.
Remove and re-install or replace the System Memory and Page Memory DIMM (
PL 35.2
).
2.
Disconnect and reconnect the NV-RAM Board and turn ON the power.
3.
If problem 116-323 still persists, replace the NV-RAM Board.
4.
After the replacement of the NV-RAM Board,
116-334
will occur. Take the corrective
actions for
116-334
in order.
5.
If problem 116-323 still persists, go to the following procedure to resolve it.
6.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
7.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
8.
Check the sw version of the controller sw - update if required
9.
Replace RAM DIMM on ESS PWB (
PL 35.2
)
10. Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-324 System Controller RAP
An exceptional Controller error shut down the processor. A fatal software exception error has
occurred in the ESS PWB (
PL 35.2
). The cause is most likely the ESS PWB (
PL 35.2
) software
failure
Initial Actions
Power Off/On
Procedure
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Turn OFF the power, then turn it ON while pressing both the [Start] and the [Stop] but-
tons. By maintaining that state for 6 seconds, the machine will automatically delete the
print data that had caused the error and then restart itself.
•
If the problem persists, carry out the following procedure:
•
Pull out and insert or replace the RAM DIMM.
•
Check the sw version of the controller sw - update if required
•
If the problem persists, replace the ESS PWB (
PL 35.2
).
•
If the problem persists, go to
116-334
.