BUS Updated 12/2011
07/2011
2-863
WorkCentre 5335 Family Service Documentation
116-346, 116-348
Status Indicator RAPs
Initial Issue
116-346 Formatter RAP
Errors are detected by the Formatter.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-348 Redirector RAP
A system function recall error is detected by the Redirector.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)