BUS Updated 12/2011
07/2011
2-876
WorkCentre 5335 Family Service Documentation
116-374, 116-375
Initial Issue
Status Indicator RAPs
116-374 Auto Switch RAP
An internal shutdown occurred after a processing error.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
•
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
–
SNTP
–
NetWare
–
Salutation IO
–
SMB
–
Port 9100
–
USB
–
lpd
–
FTP Serv
–
MailIO
–
IPP
–
Check the sw version of the controller sw - update if required
–
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-375 Formatter RAP
A response such as system function recall error is detected.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)