BUS Updated 12/2011
07/2011
2-971
WorkCentre 5335 Family Service Documentation
124-341, 124-342
Status Indicator RAPs
Initial Issue
124-341 CRUM Market Fail MCU RAP
System Fail. One of CRUM destinations is different from the others (IOT). One of the CRUM
destinations stored in three positions does not match (Data stored in the MCU Board does not
match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
•
Enter
Machine ID/Billing Data
. Master SYS1 to resolve the problem. If the problem per-
sists, replace the MCU PWB (
PL 18.2
).
(Software unavailable for
Machine ID/Billing Data
)
Replace the MCU PWB (
PL 18.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
124-342 CRUM Market Fail SYS 1 RAP
System Fail. One of CRUM destinations is different from the others (SYS 1). One of the CRUM
destinations stored in three positions does not match (Data stored in the ESS PWB (
PL 35.2
)
does not match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
Enter
Machine ID/Billing Data
. Master the MCU to resolve the problem. If the problem per-
sists, replace the Cont PWB.
(Software unavailable for
Machine ID/Billing Data
)
Extract the EEPROM from and reinsert it into the ESS PWB (
PL 35.2
). If the problem still
persists, replace the ESS PWB (
PL 35.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP