BUS Updated 12/2011
07/2011
2-976
WorkCentre 5335 Family Service Documentation
124-351, 124-352
Initial Issue
Status Indicator RAPs
124-351 CRUM OEM Fail MCU RAP
System Fail. One of CRUM OEM destinations is different from the others (IOT). One of the
CRUM OEM destinations stored in three positions does not match (Data stored in the MCU
Board does not match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
•
Enter
Machine ID/Billing Data
. Master SYS1 to resolve the problem. If the problem per-
sists, replace the MCU PWB (
PL 18.2
).
(Software unavailable for
Machine ID/Billing Data
)
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
124-352 CRUM OEM Fail SYS 1 RAP
System Fail. One of CRUM OEM destinations is different from the others (SYS 1). One of the
CRUM OEM destinations stored in three positions does not match (Data stored in the ESS
PWB (
PL 35.2
) does not match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
Enter
Machine ID/Billing Data
. Master the MCU to resolve the problem. If the problem per-
sists, replace the Cont PWB.
(Software unavailable for
Machine ID/Billing Data
)
Reload software
GP 16
. Remove the EEPROM from and reinstall it into the ESS PWB
(
PL 35.2
). If the problem still persists, replace the ESS PWB (
PL 35.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP