background image

Product description

Product instruction diagram

This temperature recorder is mainly used for temperature monitoring and recording of food and medicine storage and transportation 
environments, such as refrigerated bags, refrigerated trucks, containers, etc.
This product is connected to a computer via USB , and the recorded data is directly output as a PDF report; the temperature probe is 
built-in, powered by a CR2450 wide temperature lithium battery, and the waterproof level reaches IP67 . The product is equipped with a 
barcode.

Alarm type

Parameter description:

Record capacity: 

16000 groups (Max), there is difference due to the recording cycle. 

Delayed startup: 

record after 1 or more minutes(custom) later after logger startup.

Alarm threshold:

 the upper and lower temp limits of alarm can be set.

Alarm delay: 

Alarm starts after over-temp duration exceeds 1 or more minutes(custom), instead of immediately.

H

Over upper temp limit

Below lower temp limit

L

Single type

Cumulative type

 Single calculation of continuous over-temperature time

Cumulative calculation of all continuous over-temperature time 

Operating instructions

Long press 5 sec, the green light flashes 
5 times, logger starts normally.

Long press 5 sec, the red light flashes 5 
times, logger stops normally.

Insert the logger into the USB 
port of computer to view data 
report directly or by software.

Tear off the barcode if 
you need

Elog1/1N

Single Use Temperature Data Logger

Instruction Manual

Technical parameters

ll function-related parameters of this recorder are configured by the factory, and users can customize some of these parameters 
according to their needs;

-30°C~70°C/-22°F~158°F

-30°C~70°C/-22°F~158°F

±0.5°C/±0.9°F

-20°C~40°C/-4°F~104°F

);

1°C/1.8°F (other)

Built-in NTC

capacity of 16000 groups (maximum)

6

15

30

60

90

120

180

 

days (customizable)

single type ( Sin ), cumulative type ( Cum )

Factory default (customizable)

USB2.0/NFC

PDF format data report

Built-in CR2450 wide 

temperature lithium battery

2 years of storage and use in 

normal temperature environment

IP67

93*58*8mm (length * section * height)

about 20g

Measuring temperature

Storage temperature

Temperature 

measurement accuracy

Sensor 

Recording 

Recording period

Alarm type

Alarm threshold

Data interface

Report type

Power supply

Battery life

Protection grade

Dimensions

Weight

Note: Before the recorder is started, it is recommended to store at room temperature

NFC operation instructions (ONLY for Elog1N)

1. How to install APP?

·

Download by scanning the QR code or searching ”Xetron iCold” in app store. 

·

Register a new account then sign in.

2. How to set parameters?

·

Connect to the logger:

Click the navigation button           at the upper left corner
Select the NFC temp label (confirm the NFC function of the mobile phone is turned on)

·

Set parameters:

Click          at the upper right corner to set parameters, keep close to logger then click ”OK” to save settings
(Note: parameters only can be configured before the logger starts)

3. How to view and export data?

·

Connect logger and phone app firstly as above mentioned. View data directly once connection is successful.

·

Click            to select report format to export.

Front

*Please refer to the actual product

Back

Elog1/1N

Configuration Info

Waterproof
Plastic Bag

USB Port

LED Indicator

Button(Start/

Status/Mark/Stop)

Barcode Label

My Device

No Device

Enter Device Name or Model

NFC Temperature Tag

Place your phone above the Tag

APP

NFC

NFC Temperature Tag

EFM200000000

EFM200000000

°C

UTC+08:00

V1.2

Basic Settings

Logging Settings

Alarm Settings

Wait for be...

Max-
Min-

Configure Time

2021-08-26 14:30:45

Serial Number
Temperature Uint
Timezone
Firmware Version 

Running Time

--    Data Points

:--

23.2°C

Name

HI
L2

Threshold

8.0°C
2.0°C

Delay

00h 30m 00s
00h 30m 00s

Type

Single
Single

Logging Interval
Start Delay

00h 00m 10s
00h 00m 00s

NFC Temperature Tag

EFM200000000

EFM200000000

°C

UTC+08:00

V1.2

Basic Settings

Logging Settings

Alarm Settings

Record

Max 23.4°C
Min  23.4°C

Started

2021-08-26 14:33:20

Serial Number
Temperature Uint
Timezone
Firmware Version 

Running Time

00h 00m 00s    Data Points

1

23.4°C

Name

HI
L2

Threshold

8.0°C
2.0°C

Delay

00h 30m 00s
00h 30m 00s

Type

Single
Single

Logging Interval
Start Delay

00h 00m 10s
00h 00m 00s

Start/Stop Info

Mark Info

Status Request

Paste Area