background image

FusionServer 2488H V5 Server 
Technical White Paper 

A Appendix 

 

Issue 07 (2023-04-30) 

Copyright © xFusion Digital Technologies Co., Ltd. 

79 

 

No. 

Description 

 

Letters A to H indicate 10:00 to 17:00. 

 

Letters J to N indicate 18:00 to 22:00. 

 

Letters P to Q indicate 23:00 to 24:00. 

Indicates the serial number (two digits). 

10 

Indicates the manufacturing serial number (five digits). 

 

A.1.1.3 Sample Quick Access Tags 

Figure A-5 

Sample quick access tags 

 

 

Table A-4 

Quick access tab description 

No. 

Description 

IP address of the iBMC management network port   

Subnet mask of the iBMC management network port 

Default iBMC user name 

Default iBMC password 

Default BIOS password 

Technical support website 

P/N Code 

QR Code 

NOTE 

Scan the QR code to obtain technical support resources. 

 

Summary of Contents for FusionServer 2488H V5

Page 1: ...FusionServer 2488H V5 Server Technical White Paper Issue 07 Date 2023 04 30 xFusion Digital Technologies Co Ltd...

Page 2: ...echnologies Co Ltd shall not bear any liability resulting from the use of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All...

Page 3: ...tes a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious...

Page 4: ...ed 5 11 3 Drive Backplane Updated 6 3 Physical Specifications Updated 8 1 Security 04 2022 08 12 Optimized 6 3 Physical Specifications 03 2022 06 25 Added a figure that shows how to measure dimensions...

Page 5: ...1 Appearance 16 5 2 2 Indicators 17 5 2 3 Ports 19 5 3 Processor 20 5 4 Memory 21 5 4 1 DDR4 Memory 21 5 4 1 1 Memory Identifier 21 5 4 1 2 Memory Subsystem Architecture 23 5 4 1 3 Memory Compatibili...

Page 6: ...46 5 7 3 PCIe Slot Description 46 5 8 PSUs 48 5 9 Fans 49 5 10 LCD 49 5 11 Boards 52 5 11 1 Mainboard 52 5 11 2 Daughter Board 53 5 11 3 Drive Backplane 55 5 11 4 PSU Backplane 58 6 Product Specifica...

Page 7: ...puting enterprise and telecom service applications The 2488H V5 is ideal for applications such as databases cloud computing virtualization and in memory computing The secure compact 2488H V5 is a high...

Page 8: ...current and temperature specification limits Intel Hyper Threading Technology enables each processor core to run up to two threads improving parallel computation capability The hardware assisted Inte...

Page 9: ...to 11 PCIe 3 0 slots Availability and Serviceability Carrier class components with process expertise ensure high system reliability and availability The server uses hot swappable SAS SATA NVMe drives...

Page 10: ...figured by default Enabling disabling and setting a virtual local area network VLAN ID for this port The VLAN ID is 0 and disabled by default Configuring IPv4 addresses IPv4 address subnet mask and ga...

Page 11: ...488H V5 physical structure example 8 x 2 5 drives 1 Riser card 2 PCIe card 3 Power supply unit PSU 4 PSU backplane 5 Cable organizer 6 Chassis 7 Air duct 8 Drive Backplane 9 Fan module bracket 10 Driv...

Page 12: ...yright xFusion Digital Technologies Co Ltd 6 CPUs 1 and 2 are located on the mainboard and CPUs 3 and 4 are located on the daughter board If the server is configured with a daughter board the air duct...

Page 13: ...Logical Structure Figure 4 1 2488H V5 logical structure The server supports two or four Intel Xeon Scalable processors The server supports up to 48 memory modules The CPUs processors interconnect wit...

Page 14: ...ture Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 8 The server provides low speed I O ports such as the VGA port USB 3 0 ports and serial ports RJ45 The server provides four LOM p...

Page 15: ...igital Technologies Co Ltd 9 5 Hardware Description 5 1 Front Panel 5 2 Rear Panel 5 3 Processor 5 4 Memory 5 5 Storage 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fans 5 10 LCD 5 11 Boards 5 1 Front P...

Page 16: ...ate with an SN label 24 x 2 5 24 x SAS SATA or NVMe or 16 x SAS SATA 8 x NVMe drive configuration Figure 5 2 Front view 1 Drives 2 Slide out label plate with an SN label 25 x 2 5 SAS SATA drive config...

Page 17: ...Maskable Interrupt NMI button 6 Fault diagnosis LED 7 Health status indicator 8 UID button indicator 9 Power button indicator 24 x 2 5 24 x SAS SATA or NVMe or 16 x SAS SATA 8 x NVMe drive configurati...

Page 18: ...buttons on the front panel Sign Indicator and Button Description Fault diagnosis LED The device is operating properly Error code A component is faulty For details about error codes see the FusionServe...

Page 19: ...atus indicator Off The device is powered off or is faulty Blinking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Ste...

Page 20: ...nd will not be powered off even if the service system is powered off As long as the LOM ports are properly connected to other working network devices the network ports will remain connected and the in...

Page 21: ...ont panel Port Type QuantityNote Description VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB port USB 2 0 2 Used to connect to a USB device NOTICE Before connecting an...

Page 22: ...3 04 30 Copyright xFusion Digital Technologies Co Ltd 16 5 2 Rear Panel 5 2 1 Appearance Figure 5 10 Rear view 1 PCIe slot 1 2 PCIe slot 2 3 PCIe slot 3 4 PCIe slot 4 5 PCIe slot 5 6 PCIe slot 6 7 PCI...

Page 23: ...ent network port 5 Connection status indicator of the management network port 6 PSU indicator Indicator Description Table 5 3 Description of indicators on the rear panel Indicator Description LOM port...

Page 24: ...evice is not being located Blinking or steady blue The device is being located NOTE You can turn on or off the UID indicator by pressing the UID button or remotely running a command on the iBMC CLI He...

Page 25: ...ort 10GE SFP and 1000BASE T 4 10GE LOM service port optical and GE service port electrical For details see v VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM Serial port RJ4...

Page 26: ...to the power distribution unit PDU in the cabinet You can select the number of power supply units PSUs as required NOTE When determining the quantity of PSUs ensure that the rated power of the PSUs is...

Page 27: ...escription Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 21 Figure 5 13 Processor positions 5 4 Memory 5 4 1 DDR4 Memory 5 4 1 1 Memory Identifier You can determine the memory modu...

Page 28: ...tion 1 Capacity of the memory module 8 GB 16 GB 32 GB 64 GB 128 GB 2 Number of ranks of the memory module 1R single rank 2R dual rank 4R quad rank 8R octal rank 3 Data width on the DRAM X4 4 bit X8 8...

Page 29: ...is not populated the memory modules in secondary memory channels cannot be used Table 5 5 Memory channels CPU Memory Channel Memory Slot CPU 1 A primary DIMM000 A A DIMM001 G B primary DIMM010 B B DIM...

Page 30: ...1 H C primary DIMM220 C C DIMM221 I D primary DIMM230 D D DIMM231 J E primary DIMM240 E E DIMM241 K F primary DIMM250 F F DIMM251 L CPU 4 A primary DIMM300 A A DIMM301 G B primary DIMM310 B B DIMM311...

Page 31: ...essors 2 TB socket Other processors 1 TB socket The total memory capacity is the sum of the capacity of all DDR4 DIMMs The total memory capacity cannot exceed the maximum memory capacity supported by...

Page 32: ...the Skylake processor is used the maximum operating speed of a DIMM can reach 2666 MT s only Different CPUs possess different specifications For details about the CPU parameters see the Intel official...

Page 33: ...lti processor configuration each processor must have a valid memory mirroring configuration Memory scrubbing mode Comply with the general installation guidelines 5 4 1 5 Memory Installation Positions...

Page 34: ...Server 2488H V5 Server Technical White Paper 5 Hardware Description Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 28 Figure 5 15 Memory slots mainboard Memory slots on the daughter...

Page 35: ...Server Technical White Paper 5 Hardware Description Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 29 Figure 5 16 Memory slots daughter board Figure 5 17 DDR4 memory installation gu...

Page 36: ...essors 5 4 1 6 Memory Protection Technologies The following memory protection technologies are supported ECC Full mirroring Address range mirroring SDDC SDDC 1 Rank sparing mode Static virtual lockste...

Page 37: ...ifier Callout Description Example 1 Component name Intel DCPMM 2 Serial number 8089 A2 1839 00001931 3 Model NMA1XBD612GQS 4 Capacity 128 GB 256 GB 512 GB 5 SN QR code 8089 A2 1839 00001931 5 4 2 2 Me...

Page 38: ...IMM010 B B DIMM011 H C primary DIMM020 C C DIMM021 I D primary DIMM030 D D DIMM031 J E primary DIMM040 E E DIMM041 K F primary DIMM050 F F DIMM051 L CPU 2 A primary DIMM100 A A DIMM101 G B primary DIM...

Page 39: ...331 J E primary DIMM340 E E DIMM341 K F primary DIMM350 F F DIMM351 L 5 4 2 3 Memory Compatibility Observe the following rules when configuring DC persistent memory modules DCPMMs The DCPMMs must be u...

Page 40: ...ting Modes in FusionServer DCPMM User Guide Use the Compatibility Checker to determine the capacity type of a single memory module Table 5 8 DCPMM specifications Item Specifications Capacity per DCPMM...

Page 41: ...er it is recommended that the ratio of FM to NM be 2 1 to 16 1 Near memory NM capacity of DDR4 DIMMs used as the cache Far memory FM capacity of the DCPMMs in MM The mapping between the DCPMM and CPU...

Page 42: ...Server 2488H V5 Server Technical White Paper 5 Hardware Description Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 36 Figure 5 20 Memory slots mainboard Memory slots on the daughter...

Page 43: ...r Technical White Paper 5 Hardware Description Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 37 Figure 5 21 Memory slots daughter board Figure 5 22 DCPMM and DDR4 memory configurat...

Page 44: ...erver 2488H V5 Server Technical White Paper 5 Hardware Description Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 38 Figure 5 23 DCPMM and DDR4 memory configuration guidelines 4 pro...

Page 45: ...dress range scrub ARS DCPMM data poison DCPMM DDR T fault tolerance Faulty DCPMM isolation 5 5 Storage 5 5 1 Drive Configurations Table 5 10 Drive Configuration Configuration Maximum Front Hard Disks...

Page 46: ...in slot 4 NVMe adapter must be installed in slots 5 and 10 24 x 2 5 drive configuration 24 x NVMe Front drives 24 x 2 5 Slots 0 to 23 support NVMe drives CPU directly connected through the NVMe adapte...

Page 47: ...Description of SAS SATA drive indicators Activity Indicator Green Fault Indicator Yellow Description Off Off The drive is not in position Steady on Off The drive is detected Blinking at 4 Hz Off Data...

Page 48: ...t 2 Hz Off Data is being read from or written to the NVMe SSD Off Blinking at 2 Hz The NVMe drive is being located Steady on Off Steady on The NVMe drive is faulty If the VMD function is disabled NVMe...

Page 49: ...is faulty or not detected M 2 FRU activity indicator Off The M 2 FRU is not in position or is faulty Blinking green or light green Data is being read written or synchronized Steady green or light gree...

Page 50: ...ptical modules supported by the LOM ports The LOM ports support NC SI and PXE The LOM ports do not support forced rates The electrical LOM ports cannot be connected to power over Ethernet PoE devices...

Page 51: ...indicator Data transmission status indicator for 10GE optical port 3 5 Data transmission rate indicator for 10GE optical port 4 6 Data transmission rate indicator for 10GE optical port 3 Indicator Des...

Page 52: ...over Ethernet PoE devices such as a switch with PoE enabled Connecting such an electrical port to a PoE device may cause link communication failure or even damage the NIC Contact your local sales rep...

Page 53: ...PCIe 3 0 x8 x8 Port1A 0x43 0x 00 0x00 HHHL Slot 9 CPU 3 PCIe 3 0 x8 x8 Port2A 0xA2 0x 00 0x00 HHHL Slot 10 CPU 2 PCIe 3 0 x16 x16 Port3A 0x71 0x 00 0x00 HHHL Slot 11 CPU 2 PCIe 3 0 x8 x8 Port1C 0x43 0...

Page 54: ...uble pole fuse is provided for the PSUs with dual input live wires If the DC power supply is used purchase the DC power supply that meets the requirements of the safety standards or the DC power suppl...

Page 55: ...fan The fan speed can be adjusted The same model of fan modules must be used in a server Figure 5 35 Fan module positions 5 10 LCD Function The LCD displays the installation status and running status...

Page 56: ...unction Status Displays the port 80 status serial number component status and component alarms of the server Monitor Displays the current power CPU temperature and inlet temperature of the server Info...

Page 57: ...erver Technical White Paper 5 Hardware Description Issue 07 2023 04 30 Copyright xFusion Digital Technologies Co Ltd 51 Tab Function port For details about how to use the LCD see FusionServer 2488H V5...

Page 58: ...l Technologies Co Ltd 52 5 11 Boards 5 11 1 Mainboard Figure 5 38 2488H V5 mainboard 1 PCIe card slots 3 to 11 from right to left 2 PCIe riser slots J207 for CPU 1 and J230 for CPU 4 3 VGA connector V...

Page 59: ...237 27 Left mounting ear connector LEFT EAR CONN BOARD J115 28 PSU backplane power connector J225 J226 J239 29 PSU backplane signal connector J238 30 VROC key port J144 e a The upper one is an RJ45 se...

Page 60: ...023 04 30 Copyright xFusion Digital Technologies Co Ltd 54 CPUs 1 and 2 are on the mainboard and CPUs 3 and 4 are on the daughter board The mainboard and daughter board are interconnected through high...

Page 61: ...04 30 Copyright xFusion Digital Technologies Co Ltd 55 Figure 5 40 Connection between the daughter board and the mainboard 5 11 3 Drive Backplane 8 x 2 5 drive backplane 8 x SAS SATA Figure 5 41 8 x 2...

Page 62: ...gure 5 42 24 x 2 5 drive backplane 24 x SAS SATA BOM 03022JWW 1 SAS cable connector PORT 3B J33 2 SAS cable connector PORT 3A J39 3 SAS cable connector PORT 2B J31 4 SAS cable connector PORT 2A J30 5...

Page 63: ...ne power connector J3 11 NVMe PORT A_N3 J23 12 NVMe PORT B_N3 J27 24 x 2 5 drive backplane 24 x NVMe Figure 5 44 24 x 2 5 drive backplane 24 x NVMe 1 Slimline A connector J6 2 Slimline B connector J5...

Page 64: ...e connector is reserved PORT A J28 3 Mini SAS HD connector PORT B J29 4 Mini SAS HD connector REAR PORT J31 5 Backplane signal cable connector J1 6 Power connector J24 7 Indicator signal cable connect...

Page 65: ...upports two or four processors Intel Xeon Scalable Skylake and Cascade Lake processors Built in memory controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per...

Page 66: ...upported when the server is configured with an Avago SAS3004iMR RAID controller card The drive letter of the M 2 SSDs managed by the Avago SAS3004iMR RAID controller card can be set to sda by modifyin...

Page 67: ...B 2 GB or 4 GB cache and a supercapacitor providing power off protection to improve storage performance and data security Network Supports LOM Supports two 10GE optical ports and two GE electrical por...

Page 68: ...B storage media Video card An SM750 video chip with 32 MB display memory is integrated on the mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE SM750 is not suppor...

Page 69: ...n For details see A 3 Operating Temperature Limitations Relative humidity RH non condensing Operating humidity 8 to 90 Storage humidity within three months 8 to 85 Storage humidity within six months 8...

Page 70: ...nd pressure levels LpAm listed are measured at 23 C 73 4 F in accordance with ISO 7779 ECMA 74 and reported in accordance with ISO 9296 ECMA 109 Idle LWAd 5 3 Bels LpAm 38 1 dBA Operating LWAd 6 3 Bel...

Page 71: ...for cabinet installation 19 inch standard cabinet compliant with the International Electrotechnical Commission IEC 297 standard Cabinet width 482 6 mm 19 00 in Cabinet depth 900 mm 35 43 in Requiremen...

Page 72: ...ight for server with 24 x 2 5 drives 30 kg 66 14 lb Maximum weight for server with 25 x 2 5 drives 31 kg 68 34 lb Packaging materials 5 kg 11 02 lb Energy consumption The power consumption parameters...

Page 73: ...to application software basic middleware software and hardware The slight differences of the application software middleware basic software and hardware may cause performance inconsistency between the...

Page 74: ...ded on the device labels when installing hardware Follow them in conjunction with these Safety Instructions Only qualified personnel are allowed to perform special tasks such as performing high voltag...

Page 75: ...protective shoes as shown in Figure 8 1 Figure 8 1 Safety work wear Before touching a device wear ESD clothing and gloves or wrist strap and remove any conductive objects such as watches and jewelry...

Page 76: ...cal port without eye protection Equipment Safety Use the recommended power cables at all times Use power cables only for dedicated servers Do not use them for other devices Before operating equipment...

Page 77: ...re transportation Maximum Weight Carried by a Person To reduce the risk of personal injury comply with local regulations with regard to the maximum weight one person is permitted to carry Table 8 1 li...

Page 78: ...ports the following features and protocols KVM and text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specif...

Page 79: ...nd query operations Fault reproduction Reproduces faults to facilitate fault diagnosis Screen snapshots and videos Allows users to view screenshots and videos without login facilitating routine preven...

Page 80: ...fety EN 62368 1 2014 A11 2017 EMC EN 55032 2015 A11 2020 CISPR 32 2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR...

Page 81: ...2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1...

Page 82: ...l information and location are for reference only For details see the actual product A 1 1 On the Front Top Figure A 1 Chassis head label 1 Nameplate 2 Certificate 3 Quick access tag 4 SN NOTE For det...

Page 83: ...gital Technologies Co Ltd 77 A 1 1 1 Nameplate Figure A 2 Nameplate example Table A 1 Nameplate description No Description 1 Server Model For details see A 4 Nameplate 2 Device names 3 Power Supply Re...

Page 84: ...d 2 The value for this digit is Z which is fixed 3 Y indicates a server B indicates a semi finished server N indicates a spare part 4 The value is 0 This digit is a reserved digit 5 Indicates the year...

Page 85: ...ial number two digits 10 Indicates the manufacturing serial number five digits A 1 1 3 Sample Quick Access Tags Figure A 5 Sample quick access tags Table A 4 Quick access tab description No Descriptio...

Page 86: ...is internal label The quick guide is located on the inside of the chassis cover It describes how to remove the mainboard components important components of the chassis precautions and QR codes of tech...

Page 87: ...ely Letters P to Y indicate years 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1 0 a...

Page 88: ...ted Options supported processors of up to 165 W Options not supported PCIe SSD cards NVMe SSDs GPU cards Not supported 24 x 2 5 16 x SAS SATA 8 x NVMe drive configuration All options supported All opt...

Page 89: ...ard is installed in slot 1 the maximum operating temperature supported is 35 C 95 F A 4 Nameplate Certified Model Usage Restrictions H24H 05 Global A 5 RAS Features The server supports a variety of Re...

Page 90: ...reliability and address error detection PCIe PCIe Advanced Error Reporting Provides a PCIe advanced error reporting mechanism to improve server serviceability UPI Intel UPI Link Level Retry Provides...

Page 91: ...prove system serviceability BIOS Abstraction Layer for Error Handling The BIOS processes errors and reports error information to the OS based on specifications improving system serviceability BIOS bas...

Page 92: ...n U4430 on the mainboard CPU 3 Component in position U4370 on the mainboard CPU 4 Component in position U4401 on the mainboard N indicates the CPU number The value ranges from 1 to 4 CPUN MEM Temp CPU...

Page 93: ...R Presence FANN F Status Fan status FANN R Status RTC Battery RTC battery status An alarm is generated when the voltage is lower than 1 V CMOS battery DIMMN DIMM status DIMM N indicates the DIMM slot...

Page 94: ...e fourth output 12 V output voltage detection for soft start drive backplane module Standby 5V Mainboard standby 5 0 V voltage Standby 3 3V Mainboard standby 3 3 V voltage Standby 1 8V Mainboard stand...

Page 95: ...ves of the RAID controller card PCIe Status PCIe status PwrOn TimeOut Power on timeout PwrCap Status Power capping status HDD Backplane Drive backplane entity presence HDD BP Status Drive backplane he...

Page 96: ...or low voltage on a PCIe card BMC Time Hopping Time hopping NTP Sync Failed NTP synchronization failure and recovery events Host Loss System monitoring software iBMA link loss detection GPUN Temp GPU...

Page 97: ...oration by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Etherne...

Page 98: ...aster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI system can be transformed to a PCIe one by modifying the physical layer instea...

Page 99: ...0 Copyright xFusion Digital Technologies Co Ltd 93 B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraP...

Page 100: ...eviations C 1 A E A AC alternating current AES Advanced Encryption Standard New Instruction Set ARP Address Resolution Protocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Inpu...

Page 101: ...le DRAM dynamic random access memory DVD digital video disc E ECC error checking and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enter...

Page 102: ...oller IC Industry Canada ICMP Internet Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Inter...

Page 103: ...ork Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modula...

Page 104: ...n SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial...

Page 105: ...unbuffered dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council...

Reviews: