Windows OS: After installing the
pci-utils
package, run the
lspci
command
to obtain the B/D/F information of the server.
–
VMware OS: The
lspci
command is supported by default. You can directly
obtain the B/D/F information of the server using the
lspci
command.
5.8 PSUs
●
Supports one PSU or two PSUs.
●
Supports AC or DC PSUs.
●
Supports hot swap.
●
When two PSUs are configured, 1+1 redundancy is supported.
●
PSUs of the same P/N code must be used in a server.
●
Short-circuit protection is provided, and bipolar fuses are provided for PSUs that
support dual live wire input.
●
If you want to use a DC power supply, purchase a DC power supply that meets
the requirements of the safety standards or a DC power supply that has passed
the CCC certification.
●
For details about the optional components, consult the local sales representative
or see "OS and Parts Compatibility" in the
.
Figure 5-48
Positions of PSUs
5.9 Fan Modules
●
Supports four fan modules. Fan modules 1 and 4 each contain one fan, and fan
modules 2 and 3 each contain two fans (one upper and one lower). There are six
fans in total.
●
Supports hot swap.
●
Supports N+1 redundancy. The server runs properly when one fan fails.
●
Supports intelligent fan speed adjustment.
●
Fan modules of the same part number (P/N code) must be used in a server.
FusionServer 5288 V7 Server
Technical White Paper
5 Hardware Description
Issue 01 (2023-07-20)
Copyright © xFusion Digital Technologies Co., Ltd.
88