FusionServer CH242 V5 Compute Node
Technical White Paper
2 Features
2022-08-12
9
⚫
The compute node supports LOM that provides two 10GE ports.
Availability and Serviceability
⚫
Memory mirroring and memory module backup prevent system shutdown caused by
uncorrectable memory errors.
⚫
Data is protected using hot-swappable drives and RAID properties.
⚫
The server provides simplified O&M and efficient troubleshooting through the UID/HLY
LED indicators on the front panel, fault diagnosis LED, and iBMC WebUI.
⚫
The SSDs offer better reliability than HDDs, ensuring continued system performance.
⚫
The iBMC monitors system parameters in real time, triggers alarms, and performs
recovery actions in case of failures, minimizing system downtime.
⚫
For more information about the warranty in the Chinese market, see
Manageability and Security
⚫
The built-in iBMC monitors server operating status and provides remote management.
⚫
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault handling.
⚫
The Advanced Encryption Standard–New Instruction (AES NI) algorithm allows faster
and stronger encryption.
⚫
Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer
overflow attacks when working with a supported OS.
⚫
Intel Trusted Execution Technology enhances security using hardware-based defense
against malicious software attacks, allowing applications to run independently.
⚫
The trusted platform module (TPM) 2.0 provides advanced encryption functions, such as
digital signatures and remote authentication.
Energy Efficiency
⚫
The Intel® Xeon® Scalable processors outperform the previous-generation processors
while fitting into the same TDP.
⚫
Intel® Intelligent Power Capability allows a processor to be powered on or off based on
requirements.
⚫
Low-voltage Intel
®
Xeon
®
Scalable processors consume less energy, ideally suited for
data centers and telecommunications environments constrained by power and thermal
limitations.
⚫
The 1.2 V DDR4 RDIMMs consume 20% to 30% less power than 1.35 V DDR3
RDIMMs.
⚫
SSDs consume 80% less power than HDDs.
⚫
The hexagonal ventilation holes on the compute node provide higher ventilation density
than round holes, increasing system cooling efficiency.
⚫
Efficient voltage regulator-down (VRD) power supplies for boards minimize the energy
loss from DC/DC power conversion.
⚫
The server is protected with power capping and power control measures.