6 Product Specifications
2021-07-16
37
Item
Description
⚫
HDDs cannot be used at an altitude of over 3,050 m (10,006.44
ft).
Corrosive air
pollutant
Maximum corrosion product thickness growth rate:
⚫
Copper corrosion rate test: 300 Å/month (meeting level G1
requirements of the ANSI/ISA-71.04-2013 standard on gaseous
corrosion)
⚫
Silver corrosion rate test: 200 Å/month
Particle pollutant
⚫
The equipment room environment meets the requirements of ISO
14664-1 Class 8.
⚫
There is no explosive, conductive, magnetic, or corrosive dust in
the equipment room.
NOTE
It is recommended that the particulate pollutants in the equipment room be
monitored by a professional organization.
Acoustic noise
The data listed in the following is the declared A-weighted sound
power level (LWAd) and declared average bystander position
A-weighted sound pressure level (LpAm) when the server is
operating in a 23°C (73.4°F) ambient environment. Noise emissions
are measured in accordance with ISO 7999 (ECMA 74) and declared
in accordance with ISO 9296 (ECMA 109).
Idle:
⚫
LWAd: 6.55 Bels
⚫
LpAm: 51.2 dBA
Operating:
⚫
LWAd: 7.24 Bels
⚫
LpAm: 58.1 dBA
NOTE
Actual sound levels generated during server operation vary depending on
server configuration, load, and ambient temperature.
6.3 Physical Specifications
Table 6-3
Physical specifications
Category
Description
Dimensions (H x W x D)
⚫
86.1mm×447mm×900mm
NOTE
The chassis depth refers to the horizontal distance from the front panel
of the chassis to the I/O board of the server node.
Installation Space
⚫
Requirements for cabinet installation:
Cabinet compliant with the International Electrotechnical