FusionServer X6000 V6 Server
Technical White Paper
5 Hardware Description
2021-07-16
29
Table 5-7
NVMe drive indicators (VMD enabled)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and operating
properly.
Blinking at 2 Hz
Off
Data is being read from or written to the
NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located.
Off
Blinking at 8 Hz
The data on the secondary NVMe drive is
being rebuilt.
Steady on/Off
Steady on
The NVMe drive is faulty.
⚫
If the VMD function is disabled, NVMe drives support only orderly hot swap.
Table 5-8
NVMe drive indicators (VMD disabled)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and operating
properly.
Blinking at 2 Hz
Off
Data is being read from or written to the
NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5 Hz
The NVMe drive has completed the hot
swap process and is removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
5.4 Fan Modules
⚫
Supports four 8080/8080+ counter-rotating fan modules with high wind pressure.
⚫
The fan modules are hot-swappable.
⚫
N+1 redundancy is supported. That is, the server can work properly when a single fan
rotor fails.
⚫
The fan speed can be adjusted.
⚫
Fan modules of the same part number (P/N code) must be used in a server.