5 Hardware Description
2021-07-16
34
Figure 5-18
XH321C V6 appearance
5.7 PSUs
⚫
PSUs are installed in server nodes, so the power consumption of a server varies
depending on the server configuration:
−
When two server nodes are configured, the PSUs work in 1+1 redundancy mode.
−
When four server nodes are configured, the PSUs work in 2+2 redundancy mode.
⚫
PSUs of the same part number (P/N code) must be used in a server.
⚫
The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs
with dual input live wires.
⚫
If the DC power supply is used, purchase the DC power supply that meets the
requirements of the corresponding safety standards or the DC power supply that has
passed the CCC certification.
⚫
For details about the components that can be purchased, contact technical support.
Figure 5-19
PSU positions