FusionServer X6000 V6 Server
Technical White Paper
6 Product Specifications
2021-07-16
35
6
Product Specifications
6.2 Environmental Specifications
6.1 Technical Specifications
Table 6-1
Technical specifications
Component
Description
Form factor
2U 4-node high-density server
Server nodes
Supports a maximum of four server nodes, including XH321 V6
and XH321C V6 server nodes.
NOTE
All server nodes in a chassis must have the same configurations.
Storage
Supports a variety of drive configurations. For details, see 5.3.1
Drive Configurations.
⚫
Supports hot swap of SAS/SATA/NVMe drives.
NOTE
The NVMe drives support:
⚫
Before using the VMD function, contact technical support engineers of
the OS vendor to check whether the OS supports the VMD function. If
yes, check whether the VMD driver needs to be manually installed and
check the installation method.
⚫
Surprise hot swap if the VMD function is enabled and the latest Intel
VMD driver is installed.
⚫
Orderly hot swap if the VMD function is disabled.
⚫
If OS is installed on an NVMe SSD, BIOS can only be set to the UEFI
mode.
Fan modules
⚫
Provides four fan modules.
⚫
Supports N + 1 redundancy.
⚫
Supports hot swap (in non-stacking installation scenarios).
Summary of Contents for X6000