26
2.4.6 Special Features
Click on system management interface to enter “Special Features” setting.
Special
printing
Output
interval
A. Click to enter “Special printing”
setting .
See Appendix 1: Terms and
Definitions 9 for more information.
1) Continuous output times: system default
0 (OFF). Adjustable scope 0~9999.
Note: 0 is equal to OFF; 9999 equal to
infinite.
2) Output interval: system default OFF,
adjustable scope 0~9999mm.
Bidirectional printing:
from left to right; from right to left
1) Reverse frequency : printing direction can
be reversed automatically when the system
senses the set printing times. For example, the
set printing times is 3, when it is finished from
right to left, printing direction will change into
left to right automatically, vice versa.
system default value: 0 (off)
adjustable extent: 0 -9999
2) Reverse delay : printing delay according to
the set direction
system default value: 0 (off)
adjustable extent: 0 -999.9
it should be set before printing not during
printing process
Note: normal delay (from right to left) set in the
printing interface. see: 5.2.3;
This function is only sutable for the model of
stitched printheads and single printhead.
Continuous
output times
Continuous printing
Reverse
frequency
Reverse
delay
Bidirectional printing
Continuous printing:
2.4.7 Screen Touch Correction
Click on system management
interface to enter screen touch correction.
Note: Please correct screen touch when
there’s inaccurate touch phenomenon. Icon
“+” appears on different location on screen
guides you the screen correction. The
interface exits after screen touch correction
finished, and a message appears to
prompt screen touch correction success or
failure for your attention.