Installation of antenna:
Screw the SMA male pin of the antenna to the female SMA outlet of the router
tightly. Warning: The antenna must be screwed tightly, or the signal quality of antenna
will be influenced!
Installation of cable:
The router supports RS232 interface and 10/100M Ethernet interface. These two
interfaces both adopt RJ45 outlet and distinguish by the sign on panel. The sign of the
RS232 interface is “Console” and the sign of the 10/100M Ethernet interface is
“ETH”.
The router is equipped with a network direct cable and a console cable (optional).
Insert one end of network direct cable into RJ45 outlet with sign “ETH” of the
router, and insert the other end into the Ethernet interface of user’s device. The signal
connection of network direct cable is as follows:
RJ45-1 RJ45-2
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
Insert the RJ45 end of the console cable into the RJ45 outlet with sign “console”
of the router, and insert the DB9F end of the console cable into the RS232 serial
interface of user’s device.
Warning
: The network direct cable and the console cable mustn’t be inserted
wrongly, or the router can’t work properly.
The signal connection of the console cable is as follows:
RJ45 DB9F
1 8
2 6
3 2
4 1
5 5
6 3
7 4
8 7
The signal definition of the DB9F serial communication interface is as follows:
Pin
RS232 signal name
The direction for Router
1 DCD
output
2 RXD
output
3 TXD
input
4 DTR
input
5 GND
6 DSR
output
7 RTS
input
8 CTS
output