background image

13

ߗ

How to Use the Microscope Base

Place the microscope on a
stable table and avoid shaking
or falling.

Turn on the microscope monomer
and base.

Summary of Contents for DDL-M1

Page 1: ...DDL M1 Intelligent Microscope Operating Instruction V1 0...

Page 2: ......

Page 3: ...oscope Monomer Introduction 7 How to Use the Microscope 9 Microscope Base Introduction 11 How to Use the Microscope Base 13 Accessories and tools 16 APP Usage Guide 16 How to Use on Android iOS 17 How...

Page 4: ...id dust or foreign matter This microscope can be used by hand or can be inserted into the base as a table Pay attention to the strength of the insertion to avoid damaging the components When placing t...

Page 5: ...4 Product Introduction Microscope Installation Instructions Microscope Structure Microscope monomer Microscope base...

Page 6: ...tep 2 Hand strap facing the rear the rear microscope monomer lens slot should be aligned with the mounting hole Step 3 Holding the base with one hand Step 4 Insert it to the bottom insert the microsco...

Page 7: ...icator goes off when full During charging if there is slight heat in the microscope shell and battery please rest assured that it is normal When the microscope base is low battery the power indicator...

Page 8: ...Notice There are two magnifications to rotate the focus wheel at the same distance Lifting knob on the base and magnification minification button can also be adjusted for multiple when adjusted the fo...

Page 9: ...scope has been turned on Press for 3s again when the light goes out means the microscope has been turned off Power WiFi connection indicator When the battery is low the blue light flashes quickly When...

Page 10: ...the microscope and mobile app via WiFi Remove the lens cover Hold the upper part of the microscope with one hand the tip of the finger can be put into the hand strap to avoid falling Turn on the micr...

Page 11: ...n the lens of the microscope at the object to be observed Rotate the focus wheel with the other hand and observe the display of the phone At this time you can adjust the focus wheel to the best viewin...

Page 12: ...on window will light up which means the microscope base has been opened Turn the light brightness knob counterclockwise and hear a click the observation window will go out which means the microscope b...

Page 13: ...ces Observation Window Introduction The observation panel should be cleaned regularly to avoid oil stains which may affect the observation experience Light adjustment function description of observati...

Page 14: ...13 How to Use the Microscope Base Place the microscope on a stable table and avoid shaking or falling Turn on the microscope monomer and base...

Page 15: ...14 Connect the microscope and mobile app via WiFi Adjust the microscope lifting knob so that the microscope monomer is at a appropriate height easy to place the object of observation...

Page 16: ...ervation panel Be sure to make the side with the cover glass face up and don t put it upside down Rotate the focus wheel and observe the display of the phone At this time you can slowly adjust to the...

Page 17: ...16 Accessories and tools Notice If you purchased the simple version the accessories only contains 5 biologic section specimens 5 blank slides data cable and 2 specimen fixation clip...

Page 18: ...y version international user or Android China version Chinese user download and install it or input the following URL in the browser download and install it IOS Android downloading QR code Or enter th...

Page 19: ...lue indicator light is flashing which means the device is turned on Step 3 Connect the microscope to IOS Android device Open the smartphone s WiFi setting find the name of WiFi wifi_camera_wifi30_xxxx...

Page 20: ...m com click the third link and download the software then click the Next step Receive Install Finish Notice If you were Win10 system this software is not necessary you can directly search Camera in Wi...

Page 21: ...Step 3 Connect the device with PC via USB cable then long press Power button 3s to turn on the device Notice do not turn on the device before connect or you won t be able to see the picture if you tu...

Page 22: ...21 Step 4 Click Devices in menu bar then click USB CAMERA to select the microscope equipment name...

Page 23: ...22 For MAC Step 1 Download Software Please login https soft hvSCam com please select the HiViewSetup1 4 for mac Then download the software as shown in the figure...

Page 24: ...2 Double click and open HiView The following information will appear Then click next step Connect your microscope to a mac computer or laptop via the USB cable Then open the software If there are safe...

Page 25: ...llows System Preference Open the Security Privacy select General and AppStore and identified developers Select Open Anyway The opening interface of software is as shown in the figure Allow HiView belo...

Page 26: ...25 Step 3 Software Home Page...

Page 27: ...equipment is out of power The equipment failure Repeat connection at close range Charge the device Turn off the APP and restart the device before using it Send for repair The device cannot be charged...

Page 28: ...ure to stabilize use it after the fog disappears for a period of time Specimens were observed with foreign bodies and were not observed clearly The specimen surface is dirty and the observation panel...

Page 29: ...ith APP Unable to charge properly Microscope base The base can t turn on Unable to charge properly The illuminating dimming button doesn t work properly Notice The product accessories user interface a...

Page 30: ...erating Environment Notice At low temperature the available capacity of the battery will be reduced to varying degrees Please use the device at a temperature of 10 45 Please prevent the device from ge...

Page 31: ......

Page 32: ......

Page 33: ...uipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is...

Reviews: