XIEGU COMMUNICATIONS
6
PIN1
:
NC
PIN4
:
ALC input
PIN2
:
PTT Signal input
PIN5
:
NC
PIN3
:
Band voltage input PIN6
:
GND
○
11
TRX
Socket:
The TRX interface is connected to the transceiver output, the connector
model is SL16-K.
○
12
CIV
interface:
This interface is for XPA125 firmware updates and connection to a PC.
○
13
Handle
2.3 Display interface layout:
⑴
Input SWR value:
Displays the SWR value of the XPA125 input.
⑵
Operating voltage:
Displays the value of DC voltage supply to the XPA125.
⑶
Operating current value:
Displays the current being drawn by the XPA125.
⑷
Output stage temperature:
Displays the current temperature of the PA stage.
⑸
Output SWR value:
Displays the SWR value of the XPA125 output.