XIIMUS R-GB-IR CL User Manual. Version 1.2
10.2.2 B2:
Multiplexed colour channels output modes
Version: 2.01
Date:
7 June 2006
Firmware L1: R19 for 8.3 MHz models
K01 for 16.7 MHz models
Firmware L2: D13
Notes:
swap letters IR and GB of data values for GB-R-IR output sequence
FVAL is constantly HIGH. DVAL is identical to LVAL.
TVI XIIMUS 512CTi, 1024CTi and 2048CTi
Multiplexed Output Modes
Symbol
Parameter
Min.
Max.
Unit
T1
NewLine low (CC1)
80
-
ns
T2
Line Scan Period
3 x
512
pixels 8.3 MHz
16.7 MHz
3 x
1024
pixels 8.3 MHz
16.7 MHz
3 x
2048
pixels 8.3 MHz
16.7 MHz
71.6
36.9
133.0
67.6
256.0
129.0
-
-
-
-
-
-
µs
T3
Delay to Change of Line 8.3 MHz
1
16.7 MHz
0.7
0.8
0.9
0.9
µs
T4
Effective Integration Time
2
-
µs
T5
Delay to Exposure Control active (CC2 … CC4)
2
-
µs
1
Please note the jitter of five STROBE clock periods.
There is no jitter, if the Line Scan Period equals a multiple of six pixel clocks.
© TVI Vision, 18 October 2006 page 32 ( 57 )