XIIMUS R-GB-IR CL User Manual. Version 1.2
CTRL
DC
DC
V
in
OSC
Ctrl out
voltage
monitoring
temperature
monitoring
TIMING
GAIN CTRL
A
D
12 bits
Data out
Ctrl in
A
D
12 bits
A
D
12 bits
A
D
12 bits
A
D
12 bits
A
D
12 bits
CCD
CDS
CDS
CCD
CDS
CDS
CCD
CDS
CDS
PCU
Non volatile
memory
RS
232
2
2
Figure 3.3.
The block diagram of the camera.
The XIIMUS cameras operate in a mono-shot mode. For each rising edge of the NewLine
signal the camera responds by sending out the digital data stream of the previous line scan
period time. The output frequency is constant. The distance in time between two NewLine
edges can be set to any value above the specified minimum. The reciprocal of this time is the
line rate (Hz).
The XIIMUS cameras have been optimised for high-speed applications. Therefore best per-
formance is achieved at line rates of hundreds of lines per second or above.
Line 1
Line 3
Line 0
Line 1
Line 2
Line 3
Data out
NewLine
Line 2
Line scan rate
( CC1 )
Figure 3.4.
The relation of the data output and NewLine signals.
© TVI Vision, 18 October 2006 page 9 ( 57 )