XA Series User's manual - Page 14
6.3 Input/Output
Crossover
TYPL:
The 3 available filter types for the low frequency crossover point (high pass)
are: Butterworth, Linkwitz Riley or Bessel.
FRQL:
The filter cut-off frequency for the low frequency crossover point (high pass)
ranges from 20 to 30kHz in either 1Hz steps or 1/36 octave steps. The
frequency steps can be selected in the
System Menu
. Please refer to
page 21 for more details.
SLPL:
The filter slope for low frequency crossover point (high pass) ranges from 6
to 48dB/octave. The available slopes are 12, 24, 36 or 48 dB/octave.
TYPH:
The 3 available filter types for the high frequency crossover point (low pass)
are: Butterworth, Linkwitz Riley or Bessel.
O1:______ XOver
TYPL:Off
O1:______ XOver
FRQL:1000Hz
O1:______ XOver
SLPL:24dB
O1:______ XOver
TYPH:Off