1829XIxb1526_fc c3 Page
30 of 35
Atlas Compliance & Engineering, Inc.
1792 Little Orchard Street
San Jose, CA 95125
Phone 408.971.9743
Fax 408-971-9783
Web www.atlasce.com
front
0
back
180
left
90
right
270
Radial
Orientation
22.5
45
67.5
112.5
135
157.5
Test Table
202.5
225
247.5
292.5
315
337.5
Report of Measurements Radiated Data
The following table reports the results of the radiated measurements for the
Specialized Reprogrammable Hardware, A-U250-A64G
Table 9 - Six Highest Radiated Emission Levels
Frequency
MHz
QP Level
dB
V/m
QP Limit
dB
V/m
Margin
dB
Azimuth,
Height
Antenna,
Polarization
14538.15
51.4
59.50
-8.10
180, 1.5m
Horn, H
17834.12
50.7
59.50
-8.80
5, 1.5m
Horn, H
13182.09
50.0
59.50
-9.50
10, 1.5m
Horn, V
17614.14
49.2
59.50
-10.30
185, 1.5m
Horn, V
12974.10
49.1
59.50
-10.40
185, 1.5m
Horn, H
750.02
35.11
47.00
-11.89
175, 1.2m
BiLog, V
Test Method:
ANSI C63.4-2014
Note:
Azimuth in degrees
Spec Limit:
15.109(b & g) Class A
Height in meters
V = vertical
H = horizontal
COMMENTS: System continuously running with XBB Demo program as observed on the host PC monitor.
Ambient temperature 61°F and relative humidity of 63%. The ambient temperature of the actual EUT was
within the range of 10
to 40
C (50
to 104
F) unless the particular equipment requirements specify testing
over a different temperature range. The humidity levels were within the range of 10% to 90% relative humidity
unless the EUT operating requirements call for a different level. Emissions above 1 GHz are maximized
measurements with peak detector at 3 meter test distance.