Report of Measurements Conducted Data
The following table reports the results of the conducted measurements for the
Specialized Reprogrammable Hardware, A-U250-A64G
Table 10 - Six Highest Conducted Emission Levels
Frequency
MHz
Level
dB
V
Detector
Limit
dB
V
Margin
dB
Phase
PE
Termination
0.195
57.12
AV
66.00
-8.88
N
gnd
0.195
56.87
AV
66.00
-9.13
L1
gnd
0.195
61.60
QP
79.00
-17.40
L1
gnd
0.195
61.60
QP
79.00
-17.40
N
gnd
0.26
44.46
AV
66.00
-21.54
N
gnd
17.455
33.02
AV
60.00
-26.98
L1
gnd
Test Method:
ANSI C63.4-2014
Note:
L1 = Line side
Spec Limit:
15.107(b) Class A
N = Neutral side
QP = Quasi-Peak
AV = Average
COMMENTS: System continuously running with XBB Demo program as observed on the host PC monitor,
power source 115 VAC, 60 Hz. Ambient temperature 67
F and relative humidity of 37%. The ambient
temperature of the actual EUT was within the range of 10
to 40
C (50
to 104
F) unless the particular
equipment requirements specify testing over a different temperature range. The humidity levels were within the
range of 10% to 90% relative humidity unless the EUT operating requirements call for a different level. Test
software used to collect the emissions data from the ESPC receiver was EMI Test Software _ ESPC-K1 Version
2.02.06e from Rohde & Schwarz.