KC724 GTX Transceiver Characterization Board
15
UG932 (v2.2) October 10, 2014
Detailed Description
The GTX transceiver power rails also have corresponding inputs on the GTX transceiver
power terminal block J7 as shown in
to supply each voltage independently from
a bench-top power supply. J7 is shown in
as callout
Caution!
The 7 series GTX Module
MUST
be removed when providing external power to the GTX
transceiver rails.
Caution!
The GTX transceiver power terminal block J7 has a maximum load current contact rating
of 24A.
Information about the 7 series GTX power supply modules included with the KC724 kit is
available from these vendor websites:
•
X-Ref Target - Figure 1-7
Figure 1-7:
GTX Transceiver Power Terminal Block
UG932_c1_07_062912
1
2
GND
J7
MGTAVCC_MOD
MTTAVTT_MOD
MGTVCCAUX_MOD
VTT
3
4
5
6
7
8
9
10
11
12
NC
NC