Hardware User Guide
1-8
Xilinx Development System
Figure 1-3 Optional External Power for the MultiLINX Cable
When using an external power supply, make sure that the ground of
the supply, the MultiLINX Cable and the circuit board are all tied
together. An advantage of the external DC power supply is that no
power is taken away from the circuit board and the MultiLINX Cable
can remain powered up and does not get powered down when the
circuit board power is off.
Parallel Cable III
The Parallel Cable III is a cable assembly which contains a buffer to
protect your PC’s parallel port and a set of headers to connect to your
target system.
The cable can be used with a single CPLD or FPGA device, or several
devices connected in a daisy chain.
D0
D1
D2
D3
D4
D5
D6
D7
RDY/BUSY
CS2
CS1
CS0 (CS)
WS
GND
CCLK
DIN
RT
TDI
TCK
TMS
RST
TRIG
RD (TDO)
PWR
RS (RDWR)
CLK2-IN
CLK2-OUT
CLK1-IN
CLK1-OUT
DONE (D / P)
PROG
INIT
4
2
3
1
NOTE: Ground of Circuit Board, Power Supply and MultiLINX Cable must be tied together.
VCC
Circuit Board
XILINX device
MultiLINX Connectors
GND
VCC
External DC Power
Supply
X8928